HP AE370A HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 20 - Page 446
Setting the same speed for all ports on the switch
UPC - 882780362611
View all HP AE370A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 446 highlights
2. Enter the portCfgSpeed command. The format is: portcfgspeed [slotnumber/]portnumber, speed_level where: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). This operand is required only for directors and enterprise-class platforms. portnumber Specifies the port number relative to its slot for bladed systems. speedlevel Specifies the speed of the link: 0-Autonegotiating mode. The port automatically configures for the highest speed. 1-One Gb/s mode. Fixes the port at a speed of one Gb/s. Changing the speed to one Gb/s causes the port to be excluded from the trunk group. 2-Two Gb/s mode. Fixes the port at a speed of two Gb/s. 4-Four Gb/s mode. Fixes the port at a speed of four Gb/s. (HP StorageWorks 4/8 and 4/16 SAN Switches, Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Brocade 4Gb SAN Switch for HP c-Class BladeSystem, HP StorageWorks SAN Switch 4/32, HP StorageWorks 4/64 SAN Switch, HP StorageWorks SAN Switch 4/32B, HP StorageWorks 400 Multi-Protocol Router, and HP StorageWorks 4/256 SAN Director only.) 8-Eight Gb/s mode. Fixes the port at a speed of eight Gb/s. (HP StorageWorks 8/80 SAN Switch, HP StorageWorks 8/40 SAN Switch, HP StorageWorks 8/8 and 8/24 SAN Switches, and HP StorageWorks DC SAN Backbone Director, and HP StorageWorks DC04 SAN Director enterprise-class platforms with supported blades and 8 Gb/s SFPs installed only.) The following example sets the speed for port 3 on slot 2 to 2 Gb/s: switch:admin> portcfgspeed 2/3 2 done. switch:admin> The following example sets the speed for port 3 on slot 2 to autonegotiate: switch:admin> portcfgspeed 2/3 0 done. switch:admin> Setting the same speed for all ports on the switch 1. Connect to the switch and log in using an account assigned to the admin role. 2. Enter the switchCfgSpeed command. The format is: switchcfgspeed speedlevel where: speedlevel Specifies the speed of the link: 0-Auto-negotiating mode. The port automatically configures for the highest speed. 1-One Gb/s mode. Fixes the port at a speed of one Gb/s. Changing the speed to one Gb/s causes the port to be excluded from the trunk group. 2-Two Gb/s mode. Fixes the port at a speed of two Gb/s. 4-Four Gb/s mode. Fixes the port at a speed of four Gb/s. (HP StorageWorks 4/8 and 4/16 SAN Switches, Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Brocade 4Gb SAN Switch for HP c-Class BladeSystem, HP StorageWorks SAN Switch 4/32, HP StorageWorks SAN Switch 4/32B, and HP StorageWorks 4/256 SAN Director only.) 8-8-Eight Gb/s mode. Fixes the port at a speed of eight Gb/s. (HP StorageWorks 8/80 SAN Switch, HP StorageWorks 8/40 SAN Switch, HP StorageWorks 8/8 and 8/24 SAN Switches, and HP StorageWorks DC SAN Backbone Director, and HP StorageWorks DC04 SAN Director enterprise-class platforms with supported blades and 8 Gb/s SFPs installed only.) 442 Administering ISL trunking