HP Brocade 8/12c Fabric OS Troubleshooting and Diagnostics Guide v6.4.0 (53-10 - Page 33

Restrictions, fcPing --allpaths

Page 33 highlights

FC-FC routing connectivity 2 NOTE Superping provides an indication if all ISLs are covered. If all the ISLs are not covered, you can increase the coverage count and maximum retries to transmit, so that complete coverage of all ISLs is achieved. Consider the example below in which a few errors are recorded on ISLs 3/205-->2/25, 3/204-->2/27, 2/42-->101/3, and 2/1-->101/8. But a maximum of 100 percentage errors are recorded on internal port 0/284 on domain 2, which is the potential faulty link. ISL COVERAGE SNO ISL STATUS 1 3/123[128]--> 165/96[128] SUCCESS(5/5) 2 3/205[128]--> 2/25[128] FAILURE(7/50) 3 3/204[128--> 2/27[128] FAILURE(11/50) 4 165/99[128]--> 101/16[128] SUCCESS(5/5) 6 2/42[128]--> 101/3[128] FAILURE(10/67) 7 2/1[128]--> 101/8[128] FAILURE(8/33) INTERNAL PORT COVERAGE SNO DOMAIN INTRNL_PORT STATUS 1 2[128] 0/272 SUCCESS(40/40) 2 2[128] 0/276 SUCCESS(44/44) 3 2[128] 0/280 SUCCESS(30/30) 4 2[128] 0/284 FAILURE(20/20)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

Fabric OS Troubleshooting and Diagnostics Guide
19
53-1001769-01
FC-FC routing connectivity
2
NOTE
Superping provides an indication if all ISLs are covered. If all the ISLs are not covered, you can
increase the coverage count and maximum retries to transmit, so that complete coverage of all ISLs
is achieved.
Consider the example below in which a few errors are recorded on ISLs
3/205-->2/25
,
3/204-->2/27
,
2/42-->101/3
, and
2/1-->101/8
. But a maximum of 100 percentage
errors are recorded on internal port 0/284 on domain 2, which is the potential faulty link.
ISL COVERAGE
-------------
SNO
ISL
STATUS
-----------------------------------------------------------------------------
1
3/123[128]--> 165/96[128] SUCCESS(5/5)
2
3/205[128]--> 2/25[128]
FAILURE(7/50)
3
3/204[128--> 2/27[128]
FAILURE(11/50)
4
165/99[128]--> 101/16[128]
SUCCESS(5/5)
6
2/42[128]--> 101/3[128]
FAILURE(10/67)
7
2/1[128]--> 101/8[128]
FAILURE(8/33)
INTERNAL PORT COVERAGE
-----------------------
SNO
DOMAIN
INTRNL_PORT
STATUS
-----------------------------------------------------------------------------
1
2[128] 0/272
SUCCESS(40/40)
2
2[128] 0/276
SUCCESS(44/44)
3
2[128] 0/280
SUCCESS(30/30)
4
2[128] 0/284
FAILURE(20/20) <== 100% failure
When an echo frame is dropped, all the ISLs in the path are marked as failed. It is not possible to
determine the exact ISL link that dropped the frame. Due to this, all the ISLs in the path will record
some failures. But the ISL with the actual error, has the maximum percentage of failures, as this
ISL when selected in any possible path causes the echo frame to be dropped and accumulates a
higher failure percentage.
Restrictions
Fabric reconfiguration cannot occur while using the superping tool. It is assumed that the
fabric is stable before the
fcPing --allpaths
command is executed.
The control path for interswitch communication should be available, even if the data path for
device to device communication may have resource starvation.
When executed in a fabric with trunk ports, only the trunk master index is output to the user i.e.
individual coverage statistics of each trunk-member is not available.
All switches must have Fabric OS v6.3.0 or later.
Superping requires that the FC Echo ELS frame is supported by end-devices.
In TI Zones, when failover is disabled and superping is executed to destination device included
in the TI Zone then superping displays failures on all ISLs that are not part of the TI Zone. Also,
when superping is executed to a device that is not present in a TI Zone, failures are shown on
all ISLs that are part of any TI Zone.
This feature is not supported in interopMode 2 or 3.