HP Brocade 8/12c Fabric OS Troubleshooting and Diagnostics Guide v6.4.0 (53-10 - Page 35
Performance issues, into its local database.
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
FC-FC routing connectivity 2 Timeout: (1..30) [5] Target port is Embedded Hop In Port Domain ID (Name) Out Port BW Cost 0 E 9 (web226) 2 1G 1000 Port E 2 Tx Rx Tx Rx B/s (1s) - - 0 0 B/s (64s) - - 1 1 Txcrdz (1s) - - 0 - Txcrdz (64s) - - 0 - F/s (1s) - - 0 0 F/s (64s) - - 2743 0 Words - - 2752748 2822763 Frames - - 219849 50881 Errors - - - 0 Hop In Port Domain ID (Name) Out Port BW Cost 1 3 10 (web229) 12 1G 1000 Port 3 12 Tx Rx Tx Rx B/s (1s) 36 76 0 0 B/s (64s) 5 5 5 5 Txcrdz (1s) 0 - 0 - Txcrdz (64s) 0 - 0 - F/s (1s) 1 1 0 0 F/s (64s) 0 0 0 0 Words 240434036 2294316 2119951 2121767 Frames 20025929 54999 162338 56710 Errors - 4 - 0 Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) For details about the pathInfo command, see the Fabric OS Command Reference. Performance issues Symptom General slow-down in FCR performance and scalability. Probable cause and recommended action As LSAN zone databases get bigger, it takes more switch resources to process them. Use the enforce tag feature to prevent a backbone switch from accepting unwanted LSAN zone databases into its local database. Fabric OS Troubleshooting and Diagnostics Guide 21 53-1001769-01