Table 5-16. Solving Battery Gauge Problems, Table 5-17. Solving Display Problems
View all HP Contura 400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 278 highlights
* The recommended storage temperature range for the battery pack is -4oF to 86oF (-20oC to 30oC ). The recommended operating temperature range is 50oF to 104oF (10oC to 40oC). Table 5-16. Solving Battery Gauge Problems Problem Probable Cause Solution(s) Battery gauge appears Battery pack has been Charge the battery pack * inaccurate. partially recharged (Appendix B). too many times or NOTE: The battery gauge is computer has been in not linear. It will not Standby for an necessarily stay on each extended period of indicator the same amount time. of time. The battery gauge is based on voltage output from the battery. * The battery pack needs to be conditioned every 60 days to maintain battery gauge accuracy. Table 5-17. Solving Display Problems Problem Probable Cause Solution(s) Characters are dim. From MS-DOS: Power From MS-DOS: Change Power Management settings Management settings to is set on high or medium. custom. From Windows: Adjust From Windows: Power brightness setting in Management brightness Power Management. setting is incorrect. Brightness or Press the Fn + F9 keys. contrast (if Use arrows keys to adjust applicable) is not the brightness. Press the set properly. Fn + F8 keys. Use arrows keys to adjust the contrast. NOTE: Contrast adjustment is not applicable on models with Color TFT displays. Computer screen is in Tilt display or move direct light. computer. Screen is blank. Quick Blank is Enter password to exit initiated. QuickBlank. Another screen Press any key and/or enter blanking utility may password. be installed. Screen save was Press any key or click the initiated by Power mouse. Management due to