Remove the two Phillips M2.0×3.8 screws, Remove the power connector cable bracket
View all HP ENVY m7-u100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
(7) USB board ZIF connector cable (8) TouchPad ZIF connector cable (9) Keyboard ZIF connector cable (10) Keyboard backlight ZIF connector cable 2. Remove the three Phillips M2.0×4.8 screws (1) that secure the power connector cable bracket to the keyboard/top cover. 3. Remove the power connector cable bracket (2). 4. Remove the two Phillips M2.0×3.8 screws (3) that secure the system board to the keyboard/top cover. 5. Remove the four Phillips M2.0×4.8 screws (4) that secure the plastic support bridges and the heat sink to the keyboard/top cover. 42 Chapter 5 Removal and replacement procedures
(7)
USB board ZIF connector cable
(8)
TouchPad ZIF connector cable
(9)
Keyboard ZIF connector cable
(10)
Keyboard backlight ZIF connector cable
2.
Remove the three Phillips M2.0×4.8 screws
(1)
that secure the power connector cable bracket to
the keyboard/top cover.
3.
Remove the power connector cable bracket
(2)
.
4.
Remove the two Phillips M2.0×3.8 screws
(3)
that secure the system board to the keyboard/top cover.
5.
Remove the four Phillips M2.0×4.8 screws
(4)
that secure the plastic support bridges and the heat sink
to the keyboard/top cover.