HP Indigo 20000 CA493-00130 Rev - Page 25

From Print Care, run the, Force Leveling Calibration, BypassTableTopic > crJosActive, False

Page 25 highlights

5. Check the JOS components using the Print Care tests: ● Use Print Care to make sure that the cams are working correctly. ● Visually inspect the cams. Make sure they are fully connected to the motor axle. ● Visually inspect the flag. Make sure it is connected properly. Figure 5-1 Motor and flag area 6. At the molex connector, make sure that all of the pins are in place. Figure 5-2 Molex connector 7. Verify that the molex connector is not broken. 8. From Print Care, run the Force Leveling Calibration wizard. 9. In Systab, check the bypass statuses: ● Make sure that BypassTableTopic > crJosActive is False. ● Make sure that BypassTableTopic > crJosCalibration is False. ● Make sure that BypassTableTopic > crJosJumps is False. 10. Check the charge roller wiring at the press side: ● Check charge roller engage side - Wire W137. Troubleshooting the charge roller leveling failure - mechanical problem 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

5.
Check the JOS components using the Print Care tests:
Use Print Care to make sure that the cams are working correctly.
Visually inspect the cams. Make sure they are fully connected to the motor axle.
Visually inspect the flag. Make sure it is connected properly.
Figure 5-1
Motor and flag area
6.
At the molex connector, make sure that all of the pins are in place.
Figure 5-2
Molex connector
7.
Verify that the molex connector is not broken.
8.
From Print Care, run the
Force Leveling Calibration
wizard.
9.
In Systab, check the bypass statuses:
Make sure that
BypassTableTopic > crJosActive
is
False
.
Make sure that
BypassTableTopic > crJosCalibration
is
False
.
Make sure that
BypassTableTopic > crJosJumps
is
False
.
10.
Check the charge roller wiring at the press side:
Check charge roller engage side – Wire W137.
Troubleshooting the charge roller leveling failure – mechanical problem
23