HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 121
External Array Controller Status Change. The external controller in I/O slot %5
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
Event ID Event Severity Event Description 1149 Error External Array Accelerator Bad Data. The array accelerator board attached to the external controller in I/O slot %5 of array "%4" is reporting that it contains bad cached data.%n [SNMP TRAP: 16018 in CPQFCA.MIB] 1150 Error External Array Accelerator Battery Failed. The array accelerator board attached to the external controller in I/O slot %5 of array "%4" is reporting a battery failure.%n [SNMP TRAP: 16019 in CPQFCA.MIB] 1151 Error External Array Controller Status Change. The external controller in I/O slot %5 of array "%4" has a new status of %6.%n(Controller status values: 1=other, 2=ok, 3=failed, 4=offline, 5=redundantPathOffline)%n [SNMP TRAP: 16020 in CPQFCA.MIB] 1152 Warning Storage System Fan Module Status Change. Storage system "%4" fan module at location %5 has a new status of %6.%n(Fan module status values: 1=other, 2=notInstalled, 3=ok, 4=degraded, 5=failed)%n [SNMP TRAP: 8020 in CPQSTSYS.MIB] 1153 Warning Storage System Power Supply Status Change. Storage system "%4" power supply at location %5 has a new status of %6.%n(Power supply status values: 1=other, 2=notInstalled, 3=ok, 4=failed, 5=degraded)%n [SNMP TRAP: 8021 in CPQSTSYS.MIB] 1154 Warning Storage System Power Supply UPS Status Change. The UPS attached to storage system "%4" power supply bay %5 has a new status of %7.%n(Power supply UPS status values: 1=other, 2=noUps, 3=ok, 4=powerFailed, 5=batteryLow)%n [SNMP TRAP: 8018 in CPQSTSYS.MIB] 1155 Warning Storage System Temperature Sensor Status Change. Storage system "%4" temperature sensor at location %5 has a new status of %6 and a current temperature value of %7 celsius.%n(Temperature sensor status values: 1=other, 2=ok,3=degraded, 4=failed)%n [SNMP TRAP: 8019 in CPQSTSYS.MIB] 1156 Warning SCSI Tape Library Failed.%nThe SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has encountered an error.%n [SNMP TRAP: 5010 in CPQSCSI.MIB] 1157 Warning SCSI Tape Library OK.%nThe SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has recovered from errors.%n [SNMP TRAP: 5011 in CPQSCSI.MIB] 1158 Warning SCSI Tape Library Degraded.%nThe SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 is in a degraded condition.%n [SNMP TRAP: 5012 in CPQSCSI.MIB] 1159 Warning SCSI Tape Library Door Open.%nThe SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a door open so the unit is not operational.%n [SNMP TRAP: 5013 in CPQSCSI.MIB] 1160 Warning SCSI Tape Library Door Closed.%nThe SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a closed door and is now operational.%n [SNMP TRAP: 5014 in CPQSCSI.MIB] 1161 Error SCSI CD Library Status Change.%nThe CD Library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(CD Library status values: 1=other, 2=ok, 3=failed, 4=offline)%n [SNMP TRAP: 5015 in CPQSCSI.MIB] 1164 Warning Drive Array Controller Status Change. The Drive Array Controller in slot %4 has a new status of %5.%n(Controller status values: 1=other, 2=ok, 3=generalFailure, 4=cableProblem, 5=poweredOff)%n [SNMP TRAP: 3028 in CPQIDA.MIB] 1165 Drive Array Controller Active. The Drive Array Controller in slot %4 has become Warning the active controller.%n [SNMP TRAP: 3016 in CPQIDA.MIB] 1173 Warning Fibre Channel Tape Controller Status Change. Fibre Channel tape controller with world wide name "%4" has a new status of %5.%n(Tape controller status values: 1=other, 2=ok, 3=offline)%n [SNMP TRAP: 16008 in CPQFCA.MIB] Storage Agent Events 121