HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 55
Recommended Action: Reseat Card. Replace Card. If error persists, contact HP
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Event ID Event Severity Event Description 8818 Warning The bulk specified is warning of a potential thermal problem. Probable Cause: The bulk power supply is warning of an over temperature condition SNMP Trap: hpevtBpsWarnOt - 8818 in HPIFPTRAP.MIB. 8819 Error Malloc failed while trying to process and ERM Probable Cause: Heap space is completely used or corrupt. Contact Product Engineering. SNMP Trap: hpevtErmOutOfHeap - 8819 in HPIFPTRAP.MIB. 8821 Warning Dimm at physical location in data field is not supported on this platform. Probable Cause: Unsupported dimm in specified slot Recommended Action: Replace dimm with supported dimm. SNMP Trap: hpevtMemDimmUnsupported - 8821 in HPIFPTRAP.MIB. 8828 Error The OPTIONS component received a memory allocation error. Probable Cause: Invalidate NVRAM and reset. SNMP Trap: hpevtOptsMallocError - 8828 in HPIFPTRAP.MIB. 8837 Warning A dimm or CPU has been deconfigured or failed testing Probable Cause: A deconfigured dimm or cpu has been detected. Examine earlier events to isolate the problem. SNMP Trap: hpevtCellHwDegraded - 8837 in HPIFPTRAP.MIB. 8839 Error The cell will not join the PD Probable Cause: Broken hardware was detected and the cell integration policy combined to cause the cell to not join the PD. Recommended Action: Fix the broken hardware or change the policy using parmgr. If assistance is required, contact the HP Support Center. SNMP Trap: hpevtNotIntegratingCell 8839 in HPIFPTRAP.MIB. 8842 Warning The error context in NVM was corrupt Probable Cause: NVM is corrupted. Recommended Action: Check for other errors in the system first. Invalidate NVM and retry boot. Get the latest firmware release. SNMP Trap: hpevtIoContextCorruptErr - 8842 in HPIFPTRAP.MIB. 8843 Warning A rope went fatal from the SBA Probable Cause: Mainly a hardware problem causes this problem. Recommended Action: Replace I/O chassis. SNMP Trap: hpevtIoRopeFatal - 8843 in HPIFPTRAP.MIB. 8844 Warning A PCI bus on the system went fatal. Probable Cause: A bad card, a bad device, or a system hardware problem can cause this to occur. Card will be powered off (if possible) and the attention light on the slot will be lit indicating an error. Recommended Action: Reseat Card. Replace Card. If error persists, contact HP support. SNMP Trap: hpevtIoBusFatal - 8844 in HPIFPTRAP.MIB. 8845 Warning One of the rope units in the SBA is dead. Probable Cause: Usually hardware. SNMP Trap: hpevtIoRopeUnitFatal - 8845 in HPIFPTRAP.MIB. 8851 Warning The System Flash Write Enable bit is incorrectly set and now clearing by PDC Probable Cause: The System Flash Write Enable bit is incorrectly set by hardware and now cleared by PDC. Recommended Action: If this chassis code occurs in every boot then contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtPdhFlashWriteEnableBitSetNowCleared - 8851 in HPIFPTRAP.MIB. 8855 Error Firmware encountered a problem trying to initialize Probable Cause: Examine the related event that failed and correct that problem. SNMP Trap: hpevtFirmwareInitError - 8855 in HPIFPTRAP.MIB. 8857 Warning This means that all the cpus in the cell did not show up. Probable Cause: This will result in the cell stepping independently to collect its logs and resting itself. SNMP Trap: hpevtMcIncompleteCpuSet - 8857 in HPIFPTRAP.MIB. 8858 Warning This means that all the cells did not rendezvous during the PD rendezvous. Probable Cause: The cells will reset themselves. SNMP Trap: hpevtMcIncompleteCellSet - 8858 in HPIFPTRAP.MIB. 8859 Warning The FW tree sanity check failed during the MCA error processing. Probable Cause: The cells will independently log errors and reset. SNMP Trap: hpevtMcTreeCheckFailed - 8859 in HPIFPTRAP.MIB. Platform Agent Events 55