Failed to write the XBC Global Semaphore. Probable Cause: write to XBC failed
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Event ID Event Severity Event Description 10523 Warning Failure to get the XBC Global Semaphore address Probable Cause: Failed to get a fabric address Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. SNMP Trap: hpevtFailGetXbcGlobSemphrAddr - 10523 in HPIFPTRAP.MIB. 10524 Warning Failed to write the XBC Global Semaphore. Probable Cause: write to XBC failed Recommended Action: Contact HP Support personnel to check the XBC SNMP Trap: hpevtFailWrtXbcGlobSemphr - 10524 in HPIFPTRAP.MIB. 10528 Warning Failed to read the XBC Global Semaphore Probable Cause: System Firmware was unable to release a XBC semaphore Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. SNMP Trap: hpevtFailRdXbcGlobSemphr - 10528 in HPIFPTRAP.MIB. 10529 Warning Failed to get the address of the XBC Global Semaphore. Probable Cause: Failed to get a fabric address Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. SNMP Trap: hpevtFailGetAddrXbcGlobSemphr - 10529 in HPIFPTRAP.MIB. 10530 Warning Failed to write the XBC Global Semaphore. Probable Cause: System Firmware was unable to release a XBC semaphore Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. SNMP Trap: hpevtFailWrtXbcGlobSemphrAfrRls - 10530 in HPIFPTRAP.MIB. 10532 Warning Failed to release the XBC Global Semaphore. Probable Cause: System Firmware was unable to release a XBC semaphore Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. SNMP Trap: hpevtFailRelXbcGlobSemphr - 10532 in HPIFPTRAP.MIB. 10534 Warning Fabric phases have been executed in an invalid order. Probable Cause: System firmware failed a validation check on its routing progress Recommended Action: Collect all IPMI event logs, preferably live logs. Contact you HP Support Representative SNMP Trap: hpevtFabPhsExeInvlOrdr - 10534 in HPIFPTRAP.MIB. 10535 Warning Fabric phases have been executed in an invalid order. Data field indicates the expected phase. Probable Cause: System firmware failed a validation check on its routing progress Recommended Action: Collect all IPMI event logs, preferably live logs. Contact you HP Support Representative SNMP Trap: hpevtFabPhsExeInvlOrdrDatExpctPhs - 10535 in HPIFPTRAP.MIB. 10558 Warning Failed to get an address when opening XBC to XBC links. Probable Cause: Failed to get a fabric address Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. SNMP Trap: hpevtFailGetAddrXbcToXbcLnk - 10558 in HPIFPTRAP.MIB. 10559 Warning Failed to open a fabric link. Probable Cause: System Firmware was unable to open the crossbar link Recommended Action: Collect IPMI Event Logs. Contact your HP Support Representative to analyze the fabric. SNMP Trap: hpevtFailOpnFabLnk 10559 in HPIFPTRAP.MIB. 10560 Warning Error when writing the XBC return route. Probable Cause: write to XBC failed Recommended Action: Contact HP Support personnel to check the XBC SNMP Trap: hpevtErrWrtXbcRetRout - 10560 in HPIFPTRAP.MIB. 10561 Warning Error enabling the XBC return route Probable Cause: write to XBC failed Recommended Action: Contact HP Support personnel to check the XBC SNMP Trap: hpevtErrEnblXbcRetRout - 10561 in HPIFPTRAP.MIB. 10564 Warning Failed to disperse the routes across links. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. SNMP Trap: hpevtFailDisprsRoutAcrssLnk - 10564 in HPIFPTRAP.MIB. 10565 Warning Error setting up XBC-XBC link for routing across it. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. SNMP Trap: hpevtErrSetXbcToXbcLnkRoutX - 10565 in HPIFPTRAP.MIB. Platform Agent Events 79