HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 49
Data read from the CC Error Mask CSR Probable Cause: CC to XBC link init failure.
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Event ID Event Severity Event Description 8154 Warning EFI unable to read initial debug level from the BMC Probable Cause: SAL service to read tokens not functioning properly. Recommended Action: Reset the system. Clear SFW NVM. Upgrade system firmware. SNMP Trap: hpevtEfiDebugLevelTokenErr - 8154 in HPIFPTRAP.MIB. 8156 Error A XBC port was unexpectedly found to not be landmined. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane SNMP Trap: hpevtXbcPortNotLandmined - 8156 in HPIFPTRAP.MIB. 8159 Error An invalid number of XBC ports were landmined in the system. Probable Cause: Hardware failure: link, crossbar chip, or cell. Recommended Action: Check for hardware failures. Reset backplane to re-initialize fabric. SNMP Trap: hpevtFabricValidateError - 8159 in HPIFPTRAP.MIB. 8184 Error The backplane was not recognized as one that contains fabric Probable Cause: An unrecognized backplane is installed. Recommended Action: Contact HP Support Personnel to determine why the backplane was unrecognized. SNMP Trap: hpevtFabricISRInvalidBkp - 8184 in HPIFPTRAP.MIB. 8186 Warning Writing the XIN Error Mask Register to zero failed Probable Cause: CC Write Failure. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricXinWrZeroErrMaskError - 8186 in HPIFPTRAP.MIB. 8187 Error Dumping error info. Read status of the Primary Mode Register Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link SNMP Trap: hpevtFabricCcPriModeRegRdStatus - 8187 in HPIFPTRAP.MIB. 8188 Error Data read from the CC Primary Mode CSR Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link SNMP Trap: hpevtFabricCcPriModeRegRdData - 8188 in HPIFPTRAP.MIB. 8189 Error Dumping error info. Read status of the CC Error Mask Register Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link SNMP Trap: hpevtFabricCcErrMaskRegRdStatus - 8189 in HPIFPTRAP.MIB. 8190 Error Data read from the CC Error Mask CSR Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link SNMP Trap: hpevtFabricCcErrMaskRegRdData - 8190 in HPIFPTRAP.MIB. 8194 Warning The link could not be crossed upon first attempt Probable Cause: The neighbor port is not routable. The port is either: not connected, landmined, in FE, or contains an SBE or LPE. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricXingNeighborPortBad - 8194 in HPIFPTRAP.MIB. 8195 Error Failed reading an XBC forward progress register Probable Cause: Fabric access error Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricISRRdFwdProgErr - 8195 in HPIFPTRAP.MIB. 8198 Error Could not find an adjacent XBC due to broken fabric links Probable Cause: Possible crossbar failure Recommended Action: Contact HP Support personnel to analyze the crossbar. SNMP Trap: hpevtFabricGetNeighborMaxLinksBroken - 8198 in HPIFPTRAP.MIB. 8199 Warning The run-time verification of a programming assumption has failed. Probable Cause: Hardware in unknown state, or programming bug found. Recommended Action: Upgrade PM firmware to latest revision. If already at current revision, replace UGUY board. SNMP Trap: hpevtPmAssertionFailed - 8199 in HPIFPTRAP.MIB. 8200 Warning An unknown error has been detected by the PDHC firmware. Probable Cause: Hardware in unknown state, or programming bug found. Recommended Action: Upgrade PM firmware to latest revision. If already at current revision, replace UGUY board. SNMP Trap: hpevtPmFirmwareUnknownErr - 8200 in HPIFPTRAP.MIB. 8202 Error Data field contains data meant for firmware debug only. Probable Cause: Debug event. Recommended Action: Contact your hp support representative. SNMP Trap: hpevtPmCriticalDebug - 8202 in HPIFPTRAP.MIB. Platform Agent Events 49