No I/O port space region found in the MDT Probable Cause: EFI/SAL handoff
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Event ID Event Severity Event Description 5714 Error EFI USB HCD interrupt service has detected the host controller is hung Probable Cause: Problem with USB controller. Recommended Action: Reset the card containing the USB interface to restart the controller.Contact your HP representative to check the USB interface. SNMP Trap: hpevtEfiHcdHostHung - 5714 in HPIFPTRAP.MIB. 5715 Error The EFI/SAL handoff structure's version does not match EFI expectations Probable Cause: EFI/SAL firmware mismatch. Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtEfiSalHandoffVerMismatch - 5715 in HPIFPTRAP.MIB. 5717 Error Unable to obtain access to all RTC SAL services Probable Cause: Not all expected services are available. Mismatch between EFI and SAL versions. Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtEfiSalRtcServiceNotInit - 5717 in HPIFPTRAP.MIB. 5718 Error Unable to obtain access to all SAL timer services Probable Cause: Not all expected services are available. Mismatch between EFI and SAL versions. Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtEfiSalTimerServiceNotInit - 5718 in HPIFPTRAP.MIB. 5719 Error EFI unable to start the periodic timer Probable Cause: Internal system firmware error. Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtEfiSalStarttimerServiceNotInit - 5719 in HPIFPTRAP.MIB. 5720 Error No I/O port space region found in the MDT Probable Cause: EFI/SAL handoff structure corrupted. Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtEfiNoIoPortSpaceRegionFound 5720 in HPIFPTRAP.MIB. 5721 Error EFI reached an unimplemented section of code Probable Cause: Reached unimplemented firmware. Recommended Action: Upgrade system firmware. SNMP Trap: hpevtEfiBreakpoint - 5721 in HPIFPTRAP.MIB. 5722 Warning EFI unable to read current speedy boot settings Probable Cause: BMC not functioning properly. Recommended Action: Reset the BMC.Contact your HP representative to check the BMC. SNMP Trap: hpevtEfiSpeedyBootTokenNotRead - 5722 in HPIFPTRAP.MIB. 5723 Error Unpermitted SAL callback attempted Probable Cause: Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtEfiSalCallbackAttempted - 5723 in HPIFPTRAP.MIB. 5724 Warning EFI unable to determine frequency base of the CPU interval timer Probable Cause: Invalid timer ratio. Recommended Action: Reset system. SNMP Trap: hpevtEfiSalFreqBaseUnknown - 5724 in HPIFPTRAP.MIB. 5725 Warning EFI system events already initialized Probable Cause: Multiple attempts to initialize system events, EFI internal error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. SNMP Trap: hpevtEfiSysEventAlreadyInit - 5725 in HPIFPTRAP.MIB. 5726 Warning Unable to create internal virtualization event while initializing IPMI events Probable Cause: Out of resources. Internal EFI error. Recommended Action: Reboot system.Upgrade system firmware. SNMP Trap: hpevtEfiSysEventCreateEventFail 5726 in HPIFPTRAP.MIB. 5728 Error There was an error creating or initializing the FPGA node in firmware Probable Cause: Unable to properly initialize a system firmware node Recommended Action: Check for other errors in the system first. Invalidate NVM and retry to boot. Get the latest firmware release. SNMP Trap: hpevtFpgaNodeInitError - 5728 in HPIFPTRAP.MIB. 5729 Error Error creating the pdh ioconfig node or attaching the service to it. Probable Cause: This is likely to be a symptom of an earlier problem, or the system is out of malloc space. Recommended Action: Contact system firmware team. SNMP Trap: hpevtIoconfigNodeInitError - 5729 in HPIFPTRAP.MIB. 32 Management Agents Event Tables