HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 36
Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Event ID Event Severity Event Description 5784 Error EFI unable to initialize internal library Probable Cause: Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtEfiPosseLibNotInit - 5784 in HPIFPTRAP.MIB. 5785 Error EFI unable to initialize security system Probable Cause: BMC not responding properly. Recommended Action: Reset BMC. Contact your HP representative if problem persists. SNMP Trap: hpevtEfiSecurityNotInit - 5785 in HPIFPTRAP.MIB. 5786 Warning EFI detected invalid internal privilege level Probable Cause: SAL storage corrupted. Recommended Action: Reboot system. SNMP Trap: hpevtEfiSecInvalidSysmode 5786 in HPIFPTRAP.MIB. 5787 Warning EFI detected invalid privilege level when setting password Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. SNMP Trap: hpevtEfiSecSetPassLevelErr - 5787 in HPIFPTRAP.MIB. 5788 Error EFI MDT table is bad Probable Cause: SFW has determined that the MDT table is invalid. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. SNMP Trap: hpevtMdtBad - 5788 in HPIFPTRAP.MIB. 5790 Warning Processor has incompatible fixed core ratio Probable Cause: A CPU has a fixed ratio that is incompatible with the FSB frequency set in the chipset. Recommended Action: Contact your HP representative for support. SNMP Trap: hpevtBootCpuBadCoreFixedRatio - 5790 in HPIFPTRAP.MIB. 5791 Error All processors slated for compatibility deconfiguration Probable Cause: The user or SFW has set all CPUs to be deconfigured. Recommended Action: Look for events indicating incompatible or bad CPUs and replace them. If problem persists contact your HP representative for support. SNMP Trap: hpevtBootAllCpusSlatedForCompatDeconfig - 5791 in HPIFPTRAP.MIB. 5793 Error An unexpected or invalid value was read from a crossbar remote route table. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PDCheck the XBC chips seating reset the system replace either cells/system backplane SNMP Trap: hpevtXbcReadRemoteRouteError - 5793 in HPIFPTRAP.MIB. 5794 Error Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible bad link, crossbar, or cell connection. Recommended Action: Check crossbar and link specified in the event data. Reset cell. SNMP Trap: hpevtXbcReadNeighborInfoError - 5794 in HPIFPTRAP.MIB. 5795 Warning memory DIMM quad mis-match Probable Cause: The user installed a mismatched quad of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width). Recommended Action: Install memory ranks in quads of DIMMs that are the same size and DRAM width. SNMP Trap: hpevtMemDimmQuadMismatch - 5795 in HPIFPTRAP.MIB. 5796 Warning Firmware detected excessive errors on the DIMM. Probable Cause: Firmware detected excessive errors on the DIMM / Replace the specified DIMM SNMP Trap: hpevtMemDimmFailed - 5796 in HPIFPTRAP.MIB. 5797 Error The OE (output enable) bit was not set for a XBC port. Probable Cause: Possible firmware or link error. Recommended Action: Check XBC and port specified by event data. SNMP Trap: hpevtXbcPortOeError - 5797 in HPIFPTRAP.MIB. 5798 Error An error occurred while trying to read the PORT_STATUS CSR for a XBC port. Probable Cause: Possible bad connection between cell and backplane. Recommended Action: Check for hardware errors. Reset cell. SNMP Trap: hpevtXbcPortStatusError - 5798 in HPIFPTRAP.MIB. 5799 Error A XBC port was unexpectedly found to be landmined. Probable Cause: No action required. SNMP Trap: hpevtXbcPortLandmined - 5799 in HPIFPTRAP.MIB. 36 Management Agents Event Tables