HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 14
LDB State bad on entry Probable Cause: No action is required SNMP Trap
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Event ID Event Severity Event Description 5050 Error External interruption nest limit exceeded Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootExtIntNestLimitedExceeded - 5050 in HPIFPTRAP.MIB. 5051 Error External interrupt not serviced Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootExtIntNotServiced - 5051 in HPIFPTRAP.MIB. 5052 Error Ext int taken Probable Cause: An external interrupt has been taken Recommended Action: Reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtBootExtIntTaken - 5052 in HPIFPTRAP.MIB. 5053 Warning Forward Progress Log (FPL) access failed Probable Cause: FPL access has failed, possibly due to BMC communication interruption. SFW will not send any events to the FPL until the system is rebooted. Recommended Action: Reboot or update System and BMC FW. If problem persists contact your HP representative for support. SNMP Trap: hpevtBootFplFailed - 5053 in HPIFPTRAP.MIB. 5054 Error PSR fetch failure Probable Cause: SFW tried to read the Processor Status Register before the CPU data structure has been setup. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootGetPsrFailure - 5054 in HPIFPTRAP.MIB. 5055 Error Cell halt Probable Cause: Internal Error Recommended Action: contact your HP representative for support. SNMP Trap: hpevtBootHaltCell - 5055 in HPIFPTRAP.MIB. 5056 Warning CPU PAL incompatible with cpu Probable Cause: Incompatible PAL. Recommended Action: Update SFW or change processors SNMP Trap: hpevtBootIncompatiblePal - 5056 in HPIFPTRAP.MIB. 5057 Warning Slave is incompatible with monarch Probable Cause: Incompatible processors. Recommended Action: Replace processors. SNMP Trap: hpevtBootIncompatibleSlave - 5057 in HPIFPTRAP.MIB. 5058 Warning Interrupt clear failure Probable Cause: Interrupt clear failed. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootIntrptClearFailure - 5058 in HPIFPTRAP.MIB. 5059 Warning System Event Log (SEL) access failed Probable Cause: An IPMI event has failed. Recommended Action: Reset the BMC and reboot. If problem persists, contact HP support to troubleshoot the problem. SNMP Trap: hpevtBootIpmiEventFailed - 5059 in HPIFPTRAP.MIB. 5060 Error Trap taken Probable Cause: This will follow other events indicating some type of IVT error. Recommended Action: This event is for debugging the address, other events will determine the user action. SNMP Trap: hpevtBootIvtOffset - 5060 in HPIFPTRAP.MIB. 5063 Warning LDB State bad on entry Probable Cause: No action is required SNMP Trap: hpevtBootLdbStateBad - 5063 in HPIFPTRAP.MIB. 5064 Error Interrupt with ic bit clear Probable Cause: Interrupt context was lost because the ic bit was cleared. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootLostContextInt - 5064 in HPIFPTRAP.MIB. 5065 Error Min-state registration failure Probable Cause: Registering of the processor min state save area with PAL has failed. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootMinStateRegError - 5065 in HPIFPTRAP.MIB. 5067 Warning Boot monarch timed out Probable Cause: The monarch has timed out. Recommended Action: No action is required. Replace CPU if problem persists, system will reboot after this event. SNMP Trap: hpevtBootMonarchTimeout - 5067 in HPIFPTRAP.MIB. 14 Management Agents Event Tables