HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 42
No Cabinet Start, Insufficient IO Fans Probable Cause: The number of IO fans required
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Event ID Event Severity Event Description 7784 Error No Cabinet Start, Insufficient IO Fans Probable Cause: The number of IO fans required is a hard number. It is not dependent upon the number of entities installed in a Cabinet. The Utilities Subsystem is not allowing the cabinet to power up due to an insufficient number of installed IO fans. Recommended Action: Install missing IO fans, or if proper number installed, troubleshoot IO fan presence detection. SNMP Trap: hpevtAbortStartIofan - 7784 in HPIFPTRAP.MIB. 7786 Warning AC power to the PDCA was removed. Data Byte 3 specifies PDCA number. Probable Cause: Power source supplying AC to the PDCA has failed. Recommended Action: Troubleshoot AC power problem. SNMP Trap: hpevtAcDeleted - 7786 in HPIFPTRAP.MIB. 7791 Warning Cabinet Main Blower Failed Probable Cause: Cabinet Blower Failed Recommended Action: Replace failed blower module as soon as possible following the Blower Module Remove and Replace Procedures. SNMP Trap: hpevtBlowrFail - 7791 in HPIFPTRAP.MIB. 7793 Warning 48 Volt Converter Failed. Data Byte 3 specifies PDCA number. Probable Cause: The PDCA identified has failed. This will be evident by many BPS_FAIL codes and probably a AC_DELETED code in the Event Log. Recommended Action: Contact HP Support personnel to troubleshoot problem SNMP Trap: hpevtBpsFail48flt - 7793 in HPIFPTRAP.MIB. 7795 Warning Fan failed in designated Bulk Power Supply Probable Cause: Fan failure or fan obstructed Recommended Action: If fan is obstructed, remove obstruction. If no obstruction, Contact HP Support personnel to troubleshoot problem. SNMP Trap: hpevtBpsFailFanflt - 7795 in HPIFPTRAP.MIB. 7796 Warning 1 Side Converter Over Temp Probable Cause: If this code is not accompanied by other codes pointing to the same Bulk Power Supply, then it is an internal component failure. Recommended Action: Contact HP Support personnel to troubleshoot problem. SNMP Trap: hpevtBpsFailOt - 7796 in HPIFPTRAP.MIB. 7798 Warning Bulk Power Supplies are not Redundant. Probable Cause: Entities were added to the cabinet, increasing the estimated Power Consumption. Or, a non-functional GSP bus entity has become functional, providing previously missing power consumption information. Recommended Action: Purchase and install a Bulk Power Supply, if redundancy is desired. SNMP Trap: hpevtBpsNotRedundant - 7798 in HPIFPTRAP.MIB. 7799 Error +48V DC has exceeded its upper limit Probable Cause: The cabinet's 48V power has exceeded an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. SNMP Trap: hpevtBpsOvervoltage - 7799 in HPIFPTRAP.MIB. 7803 Error +48V DC has fallen below its lower limit Probable Cause: The cabinet's 48V power has fallen below an acceptable lower threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. SNMP Trap: hpevtBpsUndervoltage 7803 in HPIFP 7806 Warning Cabinet Fan Failed Probable Cause: Cabinet Fan Failed Recommended Action: Replace failed cabinet fan module as soon as possible following the Cabinet Fan Module Remove and Replace Procedures. SNMP Trap: hpevtCabFanFail - 7806 in HPIFPTRAP.MIB. 7822 Error Housekeeping power has exceeded expected levels. Probable Cause: The cabinet's housekeeping power has risen above an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. SNMP Trap: hpevtHkpOvervoltage - 7822 in HPIFPTRAP.MIB. 7823 Error Housekeeping power has fallen below expected levels. Probable Cause: The cabinet's housekeeping power has fallen below an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. SNMP Trap: hpevtHkpUndervoltage - 7823 in HPIFPTRAP.MIB. 42 Management Agents Event Tables