5 Power-On Self-Test and Error Messages Error Message Summary Code # Cause / Symptom 0310h 0311h 0305h 0306h 0307h 0400h 0401h 0500h 0501h 0510h 0511h 0512h 0513h 0520h 0521h 0522h 0523h 0530h 0531h 0540h 0600h 0700h 0711h 0712h 0721h 0722h Floppy A: not detected (but configured in CMOS) Floppy B: not detected (but configured in CMOS) Floppy A: plugged on Floppy B: connector General failure on floppy controller Conflict on floppy disk controller CD-ROM test failure CD-ROM not detected (but configured in CMOS) General failure on HDD onboard primary ctrl General failure on HDD onboard secondary ctrl HDD # 0 self-test error HDD # 1 self-test error HDD # 2 self-test error HDD # 3 self-test error HDD # 0 not detected (but configured in CMOS) HDD # 1 not detected (but configured in CMOS) HDD # 2 not detected (but configured in CMOS) HDD # 3 not detected (but configured in CMOS) Found a drive on slave connector only (primary) Found a drive on slave connector only (secondary) Conflict on hard disk controller Found less video memory than configured in CMOS Found less DRAM memory than at previous boot Defective SIMM (module 1, bank 1) Defective SIMM (module 2, bank 1) Defective SIMM (module 1, bank 2) Defective SIMM (module 2, bank 2) Short message (US) Flexible Disk Drive Error Flexible Disk Drive Error Flexible Disk Drive Error Flexible Disk Drive Error Flexible Disk Drive Error CD-ROM Error CD-ROM Error IDE Device Error IDE Device Error IDE Device # 0 Error IDE Device # 1 Error IDE Device # 2 Error IDE Device # 3 Error IDE Device # 0 Error IDE Device # 1 Error IDE Device # 2 Error IDE Device # 3 Error IDE Device Error IDE Device Error IDE Device Error Video Memory Error System Memory Error System Memory Error System Memory Error System Memory Error System Memory Error 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

71
5
Power-On Self-Test and Error Messages
Error Message Summary
0310h
Floppy A: not detected (but configured in CMOS)
Flexible Disk Drive Error
0311h
Floppy B: not detected (but configured in CMOS)
Flexible Disk Drive Error
0305h
Floppy A: plugged on Floppy B: connector
Flexible Disk Drive Error
0306h
General failure on floppy controller
Flexible Disk Drive Error
0307h
Conflict on floppy disk controller
Flexible Disk Drive Error
0400h
CD-ROM test failure
CD-ROM Error
0401h
CD-ROM not detected (but configured in CMOS)
CD-ROM Error
0500h
General failure on HDD onboard primary ctrl
IDE Device Error
0501h
General failure on HDD onboard secondary ctrl
IDE Device Error
0510h
HDD
#
0 self-test error
IDE Device
#
0 Error
0511h
HDD
#
1 self-test error
IDE Device
#
1 Error
0512h
HDD
#
2 self-test error
IDE Device
#
2 Error
0513h
HDD
#
3 self-test error
IDE Device
#
3 Error
0520h
HDD
#
0 not detected (but configured in CMOS)
IDE Device
#
0 Error
0521h
HDD
#
1 not detected (but configured in CMOS)
IDE Device
#
1 Error
0522h
HDD
#
2 not detected (but configured in CMOS)
IDE Device
#
2 Error
0523h
HDD
#
3 not detected (but configured in CMOS)
IDE Device
#
3 Error
0530h
Found a drive on slave connector only (primary)
IDE Device Error
0531h
Found a drive on slave connector only (secondary)
IDE Device Error
0540h
Conflict on hard disk controller
IDE Device Error
0600h
Found less video memory than configured in CMOS
Video Memory Error
0700h
Found less DRAM memory than at previous boot
System Memory Error
0711h
Defective SIMM (module 1, bank 1)
System Memory Error
0712h
Defective SIMM (module 2, bank 1)
System Memory Error
0721h
Defective SIMM (module 1, bank 2)
System Memory Error
0722h
Defective SIMM (module 2, bank 2)
System Memory Error
Code #
Cause / Symptom
Short message (US)