HP LH4r HP Netserver LH 3000 Rack Cabling Guide - Page 22

Table 2-2. LH 3000r Plugs and Receptacles Reference, See Notes Next

Page 22 highlights

Chapter 2 Rack Cabling References Table 2-2. LH 3000r Plugs and Receptacles Reference LH 3000r Jumper Cord RackStorage/12 /12FC and PDU Jumper Cord PDU Model No. Can PDUs be "Daisy Chained"? PDU cord style Recommended PDU linecord for recommended UPS Alternate PDU linecords for installations without a UPS APC UPS Model APC Redundant Switch between PDU and Source (No UPS) APC Redundant Switch between UPS and Source 100/120 VAC 8120-8378 NEMA 5-15 plug, 90" (2.3 m), 16 AWG E7742A, 90 inch (2.5 m), C13 to C14 E7675A (16 amp) No Detachable E7802A, 4.5 m NEMA 5-20P to C19 Notes 1, 2 E7802, 4.5 m Nema 520P to C19 Notes 1, 3 NS2200RM3U NS3000RM3U Notes 1, 2 SU042-1 with captive L5-30P line cords and E7802A, 4.5 m, NEMA 5-20P to C19 cords to PDU SU042-2 with captive L5-30P line cords and captive UPS L5-30P connect to L5-30R cord in switch6 200/208 VAC included C13 to C14, 2.5 m E7742A, 90 inch (2.5 m), C13 to C14 E7671A (16 amp) E7672A (16 amp, cord, and 10 amp)4 Yes, 10 amp plugs into 16 amp (use to extend the number of receptacles)4 Detachable E7803A, 4.5m, with NEMA L6-20P plug to C19 E7803A, 4.5m, NEMA L6-20P to C19 E7805A 4.5 m, NEMA L6-30P to C19 NS3000RMT3U SU045-1 with captive L6-20P line cords and E7803A, 4.5 m, L6-20P to C19 cord to PDU SU045-1 with captive line cords, captive UPS L6-20 P connects to L6-20R in switch6 230/240V included C13 to C14, 2.5 m E7742A, 90 inch (2.5 m), C13 to C14 E7671A (16 amp) E7672A (16 amp, cord, and 10 amp)4 Yes, 10 amp plugs into 16 amp (use to extend the number of receptacles)4 Detachable E7804A, 4.0m, with IEC C20 to C19 plug E7806A, 4.5 m, C19 to unterminated E7804A, 4.5 m, C20 to C19 E7809A, 4.5 m, CEE 7/7 - C195 NS2200RMI3U or NS3000RMI3U SU044-1, C20 inputs, country-specific C19 cords, and E7804A, 4 m, C20 to C19 cord to PDU SU044-1, C20 inputs, country-specific C19 cords, and E7804A, 4 m C20 to C19 jumper cord to UPS6 See Notes Next Page 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

Chapter 2
Rack Cabling References
18
Table 2-2. LH 3000r Plugs and Receptacles Reference
100/120 VAC
200/208 VAC
230/240V
LH 3000r Jumper Cord
8120-8378 NEMA 5-15
plug, 90" (2.3 m), 16
AWG
included
C13 to C14, 2.5 m
included
C13 to C14, 2.5 m
RackStorage/12 -
/12FC and PDU
Jumper Cord
E7742A, 90 inch (2.5 m),
C13 to C14
E7742A, 90 inch (2.5 m),
C13 to C14
E7742A, 90 inch (2.5 m),
C13 to C14
PDU Model No.
E7675A (16 amp)
E7671A (16 amp)
E7672A (16 amp, cord,
and 10 amp)
4
E7671A (16 amp)
E7672A (16 amp, cord,
and 10 amp)
4
Can PDUs be "Daisy
Chained"?
No
Yes, 10 amp plugs into
16 amp (use to extend
the number of
receptacles)
4
Yes, 10 amp
plugs into 16
amp (use to
extend the
number of
receptacles)
4
PDU cord style
Detachable
Detachable
Detachable
Recommended PDU
linecord for
recommended UPS
E7802A, 4.5 m NEMA
5-20P to C19
Notes 1, 2
E7803A, 4.5m, with
NEMA L6-20P plug to
C19
E7804A, 4.0m, with IEC
C20 to C19 plug
E7802, 4.5 m Nema 5-
20P to C19
Notes 1, 3
E7803A, 4.5m, NEMA
L6-20P to C19
E7806A, 4.5 m, C19 to
unterminated
E7805A 4.5 m, NEMA
L6-30P to C19
E7804A, 4.5 m, C20 to
C19
Alternate PDU
linecords for
installations without a
UPS
E7809A, 4.5 m, CEE 7/7
- C19
5
APC UPS Model
NS2200RM3U
NS3000RM3U
Notes 1, 2
NS3000RMT3U
NS2200RMI3U or
NS3000RMI3U
APC Redundant
Switch between PDU
and Source (No UPS)
SU042-1 with captive
L5-30P line cords and
E7802A, 4.5 m, NEMA
5-20P to C19 cords to
PDU
SU045-1 with captive
L6-20P line cords and
E7803A, 4.5 m, L6-20P
to C19 cord to PDU
SU044-1, C20 inputs,
country-specific C19
cords, and E7804A, 4 m,
C20 to C19 cord to PDU
APC Redundant
Switch between UPS
and Source
SU042-2 with captive
L5-30P line cords and
captive UPS L5-30P
connect to L5-30R cord
in switch
6
SU045-1 with captive
line cords, captive UPS
L6-20 P connects to
L6-20R in switch
6
SU044-1, C20 inputs,
country-specific C19
cords, and E7804A, 4 m
C20 to C19 jumper cord
to UPS
6
See Notes Next Page