System LEDs and Switches To erase all system configuration settings: 1. Power down the server. 2. Remove the access panel. 3. Set the position 6 lever to the on position. 4. Power up the server and wait for the system to display a message confirming that the maintenance switch has been set. 5. Power down the server. 6. Reset the position 6 lever to the default position (off). 7. Power up the server. 8. Press the F9 key to run RBSU and reset all system configuration settings. For instructions on using RBSU to reset system configuration settings, see Chapter 8, "Server Configuration and Utilities." HP ProLiant ML530 Generation 2 Server Setup and Installation Guide C-23