HP Model 755/125cL hp DDS-2 tape drive user's guide (a1658-90689) - Page 30

Data Cassettes

Page 30 highlights

Using Your DDS Drive LEDs The front panel has two colored LEDs: the Tape Light and the Clean/Attention Light. The Tape Light flashes green to show activity (loading, unloading, reading, and writing). Steady green means a cartridge is loaded. The Clean/Attention Light flashes amber to indicate head cleaning is needed or a cartridge is near the end of its life. Steady amber means a hard fault. Table 2-1. LED Display Codes Tape Light Any Any Clean/ Meaning Attention Activity - load or unload Activity - read or write Cartridge loaded Cleaning needed Fault Key OFF Steady Green Steady Amber Flashing Green 1/2 sec on, 1/2 sec off Flashing Amber 1/2 sec on, 1/2 sec off Fast Flash Green 1/4 sec on, 1/4 sec off Data Cassettes Media Life HP DDS data cassettes are currently specified to 2000 passes over any part of the tape under optimal environmental conditions (50% relative humidity, 22 degrees C). During a tape operation, any one area of the tape may have multiple passes over the heads, this translates into approximately 200 to 300 backups or restores. Under certain conditions, the life of your data cassette is less than 200 to 300 backups or restores. Replace your data cassettes after 100 backups or restores if your operating conditions meet any of the following criteria: 2-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

Using Y
our DDS Drive
2–3
LEDs
The front panel has two colored LEDs: the Tape Light and the Clean/Attention Light. The
Tape Light flashes
green
to show activity (loading, unloading, reading, and writing).
Steady green means a cartridge is loaded.
The Clean/Attention Light flashes
amber
to indicate head cleaning is needed or a
cartridge is near the end of its life. Steady amber means a hard fault.
Table 2–1.
LED Display Codes
Tape
Clean/
Meaning
Light
Attention
Activity
– load or unload
Activity – read or write
Cartridge loaded
Cleaning needed
Fault
Key
OFF
Steady Green
Steady Amber
Flashing Green
1/2 sec on, 1/2 sec of
f
Flashing Amber
1/2 sec on, 1/2 sec of
f
Fast Flash Green
1/4 sec on, 1/4 sec of
f
Any
Any
Data Cassettes
Media Life
HP DDS data cassettes are currently specified to 2000 passes over any part of the tape
under optimal environmental conditions (50% relative humidity, 22 degrees C). During a
tape operation, any one area of the tape may have multiple passes over the heads, this
translates into approximately 200 to 300 backups or restores.
Under certain conditions, the life of your data cassette is less than 200 to 300 backups or
restores. Replace your data cassettes after 100 backups or restores if your operating
conditions meet any of the following criteria: