HP ProLiant BL420c HP ProLiant BL420c Gen8 Server Blade User Guide - Page 38
Configuring Arrays on HP, Smart Array Controllers Reference Guide, CAUTION, IMPORTANT
View all HP ProLiant BL420c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
5. If another SAS controller is installed, do the following: a. Flush the original cache to remove all data. For more information, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). CAUTION: Always be sure that both captive screws are disengaged before removing the SAS controller. Failure to disengage the screws may result in damage to the SAS controller. b. Disengage the SAS controller captive screws and use the handle to remove the SAS controller. c. Locate and remove the cache module ("System board components" on page 8) associated with the original SAS controller, if installed. This cache module is located near the rear of the system board and is not required when installing an HP Smart Array P220i Controller. IMPORTANT: Always close the SAS controller handle before installing the SAS controller. Hardware options installation 38