HP ProLiant SL2500 HP Scripting Toolkit 9.60 for Windows User Guide - Page 44

Controller does not support RAID Array ID., Invalid RAID Array ID.

Page 44 highlights

Error code Error message Comment or clarification 2844 Invalid stripe size. The specified stripe size is invalid, or not supported by the current RAID level, or not possible with the current configuration. 2845 Invalid sectors. The specified MaxBoot setting is invalid or is not possible with the current configuration. 2846 Cannot change logical drive sectors. You cannot change the MaxBoot setting on a configured logical drive because doing so causes data loss. 2847 Invalid array accelerator setting. The specified array accelerator setting is invalid or is not supported by the current configuration. 2848 Cannot change logical drive array accelerator setting. You cannot change the array accelerator setting for the current controller configuration. 2849 Invalid ClearConfigurationWithDataLoss - parameter. 2850 Controller does not support RAID Array ID. - 2851 Invalid RAID Array ID. The scripted RAID Array ID is invalid. Use characters from the set a-z, A-Z, 0-9 and [space]. The ID cannot end with a space character or exceed the maximum number of characters allowed by the controller. 2852 Invalid SSP state. - 2853 Cannot change SSP settings. - 2854 Invalid SSP adapter ID. - 2855 Controller does not support logical drive - SSP states. Use the SSPState controller command to set the controller SSP state. 2856 Controller does not support controller SSP - state. Use the LogicalDriveSSPState logical drive command to set SSP states for each logical drive. 2857 Invalid surface scan delay. - 2861 Controller does not support redundancy The controller is not redundant or does not support settings. redundancy settings. 2864 Invalid preferred path mode. The specified value for the preferred path mode is not valid, or the controller is not available. 2865 Invalid preferred path. The specified preferred path is not a valid chassis slot for an available active controller, or the controller is not available. 2866 Failure opening capture file . - 2867 Failure opening input file . - 2868 Failure opening error file . - 2869 command expected. The command is missing or in the wrong place in the script file. 2870 is not a supported command. - 2871 is not a Controller command. The command does not belong in the Controller section of the script file. 2872 is not an Array command. The command does not belong in the Array section of the script file. 44 Scripting Toolkit utilities

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Comment or clarification
Error message
Error code
The specified stripe size is invalid, or not supported by the
current RAID level, or not possible with the current
configuration.
Invalid stripe size.
2844
The specified MaxBoot setting is invalid or is not possible
with the current configuration.
Invalid sectors.
2845
You cannot change the MaxBoot setting on a configured
logical drive because doing so causes data loss.
Cannot change logical drive sectors.
2846
The specified array accelerator setting is invalid or is not
supported by the current configuration.
Invalid array accelerator setting.
2847
You cannot change the array accelerator setting for the
current controller configuration.
Cannot change logical drive array
accelerator setting.
2848
Invalid ClearConfigurationWithDataLoss
parameter.
2849
Controller does not support RAID Array ID.
2850
The scripted RAID Array ID is invalid. Use characters from
the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +, :, ., /, and
Invalid RAID Array ID.
2851
[space]. The ID cannot end with a space character or exceed
the maximum number of characters allowed by the controller.
Invalid SSP state.
2852
Cannot change SSP settings.
2853
Invalid SSP adapter ID.
2854
Controller does not support logical drive
SSP states. Use the SSPState controller
command to set the controller SSP state.
2855
Controller does not support controller SSP
state. Use the LogicalDriveSSPState logical
2856
drive command to set SSP states for each
logical drive.
Invalid surface scan delay.
2857
The controller is not redundant or does not support
redundancy settings.
Controller does not support redundancy
settings.
2861
The specified value for the preferred path mode is not valid,
or the controller is not available.
Invalid preferred path mode.
2864
The specified preferred path is not a valid chassis slot for an
available active controller, or the controller is not available.
Invalid preferred path.
2865
Failure opening capture file
<text>
.
2866
Failure opening input file
<text>
.
2867
Failure opening error file
<text>
.
2868
The
<text>
command is missing or in the wrong place in the
script file.
<text>
command expected.
2869
<text>
is not a supported command.
2870
The
<text>
command does not belong in the Controller section
of the script file.
<text>
is not a Controller command.
2871
The
<text>
command does not belong in the Array section
of the script file.
<text>
is not an Array command.
2872
44
Scripting Toolkit utilities