HP ProLiant SL2500 HP Scripting Toolkit 9.60 for Windows User Guide - Page 44
Controller does not support RAID Array ID., Invalid RAID Array ID.
View all HP ProLiant SL2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Error code Error message Comment or clarification 2844 Invalid stripe size. The specified stripe size is invalid, or not supported by the current RAID level, or not possible with the current configuration. 2845 Invalid sectors. The specified MaxBoot setting is invalid or is not possible with the current configuration. 2846 Cannot change logical drive sectors. You cannot change the MaxBoot setting on a configured logical drive because doing so causes data loss. 2847 Invalid array accelerator setting. The specified array accelerator setting is invalid or is not supported by the current configuration. 2848 Cannot change logical drive array accelerator setting. You cannot change the array accelerator setting for the current controller configuration. 2849 Invalid ClearConfigurationWithDataLoss - parameter. 2850 Controller does not support RAID Array ID. - 2851 Invalid RAID Array ID. The scripted RAID Array ID is invalid. Use characters from the set a-z, A-Z, 0-9 and [space]. The ID cannot end with a space character or exceed the maximum number of characters allowed by the controller. 2852 Invalid SSP state. - 2853 Cannot change SSP settings. - 2854 Invalid SSP adapter ID. - 2855 Controller does not support logical drive - SSP states. Use the SSPState controller command to set the controller SSP state. 2856 Controller does not support controller SSP - state. Use the LogicalDriveSSPState logical drive command to set SSP states for each logical drive. 2857 Invalid surface scan delay. - 2861 Controller does not support redundancy The controller is not redundant or does not support settings. redundancy settings. 2864 Invalid preferred path mode. The specified value for the preferred path mode is not valid, or the controller is not available. 2865 Invalid preferred path. The specified preferred path is not a valid chassis slot for an available active controller, or the controller is not available. 2866 Failure opening capture file . - 2867 Failure opening input file . - 2868 Failure opening error file . - 2869 command expected. The command is missing or in the wrong place in the script file. 2870 is not a supported command. - 2871 is not a Controller command. The command does not belong in the Controller section of the script file. 2872 is not an Array command. The command does not belong in the Array section of the script file. 44 Scripting Toolkit utilities