HP ProLiant SL4545 HP ProLiant SL4545 G7 Server Node User Guide
HP ProLiant SL4545 Manual
View all HP ProLiant SL4545 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant SL4545 manual content summary:
- HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 1
HP ProLiant SL4545 G7 Server Node User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 3
Remove the processor air baffle ...21 Setup...22 Optional installation services ...22 Rack planning resources...22 Optimum environment ...22 Space ...26 Powering up and configuring the server ...26 Installing the operating system for G7 servers 26 Deploying management software ...26 Discovering - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 4
for ProLiant...45 HP ROM-Based Setup Utility...46 Array Configuration Utility ...48 Option ROM Configuration for Arrays 48 Re-entering the server serial number and product ID 49 Management tools...49 Automatic Server Recovery ...49 ROMPaq utility ...49 iLO technology...50 Redundant ROM support - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 5
to prevent electrostatic discharge 62 Specifications ...63 Environmental specifications ...63 Hot-plug power supply calculations...63 Support and other resources ...64 Before you contact HP...64 HP contact information ...64 Customer Self Repair ...64 Appendix: Install the hpahcisr driver for OS - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 6
Component identification Node component identification Front panel components Item 1 2 3 4 5 Description Hard drive bay 1 Hard drive bay 2 Node release button USB connectors (2) VGA connector Front panel LEDs and buttons Item Description 1 UID LED button Status Blue = Activated Flashing blue - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 7
Item 2 3 4 Description Node release button System Health LED Power On/Standby button and system power LED Status Off = Deactivated - Green = Normal Flashing amber = System degraded Flashing red = System critical Green = System on Amber = System is in Standby mode, but power is still applied. Off = - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 8
Front panel USB/VGA connector VGA connector Front LED connector DIMM slots DIMM slots are numbered sequentially (1 through 6) for each processor. The supported AMP modes use the alpha assignments for population order, and the slot numbers designate the DIMM slot ID for spare replacement. System - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 9
hard reset. Crash dump analysis is an essential part of eliminating reliability problems, such as hangs or crashes in OSs, device drivers, and hard reset. Resetting the system erases any information that would support root cause analysis. Systems running Microsoft® Windows® experience a blue - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 10
on chassis LEDs and connectors. For information on chassis options installation, see the HP ProLiant SL4500 Series Setup and Installation Guide. For information on component removal and replacement, see the HP ProLiant SL4500 Series Chassis Maintenance and Service Guide. Component identification 10 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 11
Front panel components • 1 node chassis Item 1 2 3 4 5 6 7 8 9 10 11 Description Node hard drives LFF drive health LED LFF drive UID Drives controlled by the array controller a. Port 1i b. Port 2i Drive display boards Node VGA connector Node USB connectors Node Power On/Standby button and system - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 12
Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Node 1 Node hard drives LFF drive health LED LFF drive UID Drives controlled by node 1 P420i array controller Node 2 Drives controlled by node 2 P420i array controller Drive display boards Node VGA connector Node USB connectors Node Power On/Standby - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 13
drive is selected. Hard drive health LEDs LED behavior Definition Off System is off. Green Amber Storage system health is good. System requires service or a fault is detected. Check hard drives, hard drive backplane, RAID controller, and system fans. UID LEDs LED behavior Off Blue flashing - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 14
Item 1 2 3 4 Description System fans I/O module Management module Power supplies • 2 node chassis Item 1 2 3 4 5 Description System fans I/O module for node 1 Management module Power supplies I/O module for node 2 I/O module connectors and LEDs • 1 Gb I/O module Component identification 14 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 15
Item 1 2 3 4 5 Description Activity LED 1Gb connectors I/O module health LED Serial connector Link LED • 10 Gb I/O module Item 1 2 3 4 5 6 7 8 9 Description 1 Gb connectors I/O module health LED QSFP 10 Gb Ethernet or 40Gb IB connector, depending on configuration SFP+ 10Gb Ethernet connector - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 16
Description Status 10Gb/40Gb link LED Green = Network link Off = No network link 10Gb/40Gb activity Flashing amber = Network activity LED Off = No network activity Management module connectors and LEDs Item 1 2 3 4 5 Description UID LED Health LED Description RCM connector (SL-APM) - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 17
Device bay numbering Power supply LED Power LED Off Green Fan LED Status • No AC power to power supply units. Check the AC power cord. • AC is present. Standby output is on; output is disabled. • Power supply failure (includes overvoltage and overtemperature) AC is present and main 12 V output is - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 18
LED color Solid amber System fan status The fan module has failed. Component identification 18 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 19
node for any upgrade or maintenance procedures, perform a backup of critical server data and programs. IMPORTANT: When the node is in standby mode, node (on page 19). CAUTION: To avoid damage to the node, always support the bottom of the node when removing it from the chassis. 2. Remove the node - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 20
c. Remove the node. CAUTION: To avoid damage to the device, do not use the removal handle to carry it. 3. Place the node on a flat, level surface. Remove the access panel To remove the component: 1. Power down the node (on page 19). 2. Remove the node ("Remove a node from the chassis" on page 19). - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 21
4. Slide the access panel toward the rear of the node, and then lift to remove the panel. Install the access panel 1. Place the access panel on top of the node. 2. Slide the access panel forward until it clicks into place. Remove the processor air baffle 1. Power down the node (on page 19). 2. - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 22
by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 23
To allow for servicing and adequate airflow, the rack to the back of another rack or row of racks. HP nodes draw in cool air through the front door and expel warm air damage. The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations in the front and rear - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 24
receptacles, are listed or certified grounding-type devices. Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a PDU that is either permanently wired to the building's branch circuit or includes a nondetachable - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 25
rails, and then install the chassis and other components. For more information, see the HP ProLiant SL4500 Series Setup and Installation Guide and the Quick Deploy Rail System Installation Instructions that ship with the rack hardware kit. Installing hardware options Install any hardware options - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 26
and configuring your system, see the HP ProLiant SL4500 Series Quick Setup Instructions and the HP ProLiant SL4500 Series Setup and Installation Guide. Powering up and configuring the server To power up the server, press the Power On/Standby button. While the server boots, RBSU and the ORCA utility - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 27
provisioning policies, do the following: • Complete the installation checklist. • Be sure that the HP ProLiant SL4545 G7 Server, switches, and associated storage resources are configured. • Verify that a supported operating system is installed. If the operating system has not been installed, see the - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 28
damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can ROM. Locate and download the latest ROM version from the HP website (http://www.hp.com/support). Follow the instructions on the website to update the system ROM. 2. Power - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 29
6. Remove the heatsink blank. Retain the heatsink blank for future use. 7. Remove the processor socket protective cover. Save the cover for future use. CAUTION: Failure to completely open the processor locking lever prevents the processor from seating during installation, leading to hardware damage. - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 30
8. Open the processor locking lever and the processor socket retaining bracket. IMPORTANT: Be sure the processor remains inside the processor installation tool. 9. If the processor has separated from the installation tool, carefully reinsert the processor into the tool. Handle the processor by the - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 31
10. Align the processor installation tool with the socket and install the processor. THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board: • Never install or remove a processor - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 32
12. Close the processor socket retaining bracket and the processor locking lever. CAUTION: Be sure to close the processor socket retaining bracket before closing the processor locking lever. The lever should close without resistance. Forcing the lever closed can damage the processor and socket, - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 33
architecture The memory subsystem in this node is divided into channels. Each processor supports three channels, and each channel supports two DIMM slots, as shown in the following table. DIMM slots in this server are identified by number and by letter. Letters identify the population order. Slot - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 34
= 1066-MT/s R = RDIMM (registered) E = UDIMM (unbuffered with ECC) L = LRDIMM (load reduced) For the latest supported memory information, see the QuickSpecs on the HP website (http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html). At the website, choose the geographic region, and then - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 35
Advanced Memory Protection options are configured in RBSU. If the requested AMP mode is not supported by the installed DIMM configuration, the node boots in Advanced ECC mode. For more information, see "HP ROM-Based Setup Utility (on page 46)." Maximum capacity DIMM type RDIMM RDIMM DIMM rank - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 36
, online spare, or lockstep memory support. Installing a DIMM CAUTION: To avoid , drive blanks, and access panel must be installed when the server is powered up. 1. Power down the node (on page page 19). To configure the memory mode, use RBSU ("HP ROM-Based Setup Utility" on page 46). Hot-plug hard - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 37
Removing a drive blank Remove the component as indicated. CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. Installing a hot-plug SATA hard drive 1. Remove the drive blank ("Removing a drive blank" on - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 38
its features, see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). Features and functions of the P420i are shared with the P420. HP Trusted Platform Module option Use these instructions to install and enable - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 39
permanent part of the system board. • When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology. For security reasons, integrity. • HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 40
5. Install the TPM board. Press down on the connector to seat the board ("System board components" on page 7). 6. Install the TPM security rivet by pressing the rivet firmly into the system board. 7. Install the access panel (on page 21). 8. Install the node into the chassis ("Installing a node into - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 41
From the Main Menu, select Server Security. 3. From the Server Security Menu, select Trusted 8. Enable the TPM in the OS. For OS-specific instructions, see the OS documentation. CAUTION: When a TPM is HP Trusted Platform Module Best Practices White Paper on the HP website (http://www.hp.com/support - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 42
Cabling Personality board cabling SATA cabling Internal power cabling The power cable routes over the HDD LED cable and SATA cables. Connect and route the cables in the following order: 1. HDD data LED cable (bottom) 2. SATA cables Cabling 42 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 43
following order: 1. RPS cable and front LED cable (bottom) 2. SFF backplane power cable 3. USB/VGA cable Front LED cabling WARNING: Only authorized technicians trained by HP should attempt to replace this component. Cabling 43 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 44
SFF backplane power cabling The SFF backplane power cable routes on top of the RPS cable and front LED cable, and under the USB/VGA cable. Secure the SFF backplane power cable in the plastic clip provided. Connect and route the cables in the following order: 1. RPS cable and front LED cable (bottom) - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 45
HP Service Pack for ProLiant SPP is a release set that contains a comprehensive collection of firmware and system software components, all tested together as a single solution stack for HP ProLiant servers Deploys firmware and software together • Supports offline and online deployment • Deploys - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 46
Setup Utility RBSU is a configuration utility embedded in HP ProLiant servers that performs a wide range of configuration activities that on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). Using RBSU - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 47
For more information about BIOS Serial Console, see the BIOS Serial Console User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). Configuring AMP modes Not all ProLiant servers support all AMP modes. RBSU provides menu options only for the modes - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 48
service • Supports online HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 49
HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en). Re-entering the server should only be used by qualified service personnel. This value should always screen, ABEND (does not apply to HP ProLiant DL980 Servers), or panic. A system fail-safe timer - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 50
. Then, enter your product name in the Find an HP product field and click Go. iLO technology The iLO subsystem is a standard component of selected ProLiant servers that provides server health and remote server manageability. The iLO subsystem includes an intelligent microprocessor, secure memory - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 51
USB support Diagnostic tools HP Insight Diagnostics HP Insight Diagnostics is a proactive node management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify node installations, troubleshoot problems - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 52
comprehensive remote monitoring and proactive service support for nearly all HP servers, storage, network, and SAN environments, plus selected non-HP servers that have a support obligation with HP. It is integrated with HP Systems Insight Manager. A dedicated server is recommended to host both - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 53
or updating device drivers. The node includes new hardware that may not have driver support on all OS installation media. Drivers, ROM images, and value-add software can be downloaded as part of an SPP ("HP Service Pack for ProLiant" on page 45). If you are installing drivers from SPP, be sure that - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 54
Care Pack HP Care Pack Services offer upgraded service levels to extend and expand bundled services with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. For more information, see the HP website (http://www.hp.com/services/carepack). Software and - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 55
RBSU. To replace the component, reverse the removal procedure. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. System battery 55 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 56
computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. FCC rating label The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 57
this product, contact us by mail or telephone: • Hewlett-Packard Company P. O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 • 1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.) For questions regarding this FCC declaration, contact us - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 58
is valid if powered with the correct CE-marked AC adapter provided by HP. Compliance with these directives implies conformity to applicable harmonized European standards (European , your household waste disposal service or the shop where you purchased the product. Regulatory compliance notices 58 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 59
Japanese notice BSMI notice Korean notice Class A equipment Class B equipment Regulatory compliance notices 59 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 60
other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure Do not try to open the module enclosure. There are no user-serviceable components inside. • Do not operate controls, make adjustments, or perform - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 61
authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 62
workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 63
minimum of 70 kPa. Hot-plug power supply calculations For hot-plug power supply specifications and calculators to determine electrical and heat loading for the server, refer to the HP Enterprise Configurator website (http://h30099.www3 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 64
Health System log (HP ProLiant Gen8 or later products) Download and have available an Active Health System log for 3 days before the failure was detected. For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website (http://www.hp.com/go/ilo/docs - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 65
required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. Facultatif - Piè - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 66
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. Support and other resources 66 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 67
Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 68
propio cliente de HP, póngase en HP siguiente (http://www.hp.com/go/selfrepair). Customer Self Repair Veel onderdelen in HP HP (of een HP Service HP Service HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP stico, a HP (ou fornecedores/parceiros de serviço da HP) concluir - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 69
transportadora/serviço postal a ser utilizado. Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair). Support and other resources 69 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 70
Support and other resources 70 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 71
Support and other resources 71 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 72
that is displayed, press any key to continue. 6. Select Enable SATA RAID support. 7. Press ESC to save and exit RBSU. Creating a drivers diskette for Microsoft Windows Server 2008/2008 R2 driver USB key link to create the drivers diskette for the Windows 2008 R2 x64 OS. 4. When the HP USB Punchout - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 73
Select the operating system you want to install screen is displayed, select Windows Server 2008 R2 Enterprise (Full Installation). 10. Click Next. 11. When the SmartStart 8.70 image on a client server with any Linux operating system. Click Agree to accept the HP End User License Agreement. 2. Select - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 74
SATA RAID functionality in RBSU" on page 72). 2. Create a logical volume for the driver using ORCA. 3. Mount the Linux OS and boot the server using the Linux OS. 4. Select Installation. 5. Enter the following command: o For SLES, enter broken_modules=ahci o For RHEL5, enter linux dd o For RHEL6 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 75
Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery CSA Canadian Standards Association CSR Customer Self Repair DDR double data rate HP SIM HP Systems Insight Manager IEC International Electrotechnical Commission iLO Integrated Lights-Out IML - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 76
ORCA Option ROM Configuration for Arrays POST Power-On Self Test QSFP quad small form-factor pluggable RBSU ROM-Based Setup Utility RDIMM registered dual in-line memory module SAS serial attached SCSI SATA serial ATA SFF small form factor SFP small form-factor pluggable SFP+ small form-factor - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 77
USB universal serial bus VCA Version Control Agent Acronyms and abbreviations 77 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 78
documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 78 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 79
22, 54 Change Control 53 chassis components 10 chassis, installing server 25 chassis, removing server 19 Chinese notice 60 class A equipment 56 class B DIMM slots 8, 35 DIMMs 33, 36 DIMMs, installation 36 discovering HP devices 27 disposal, waste 58 documentation 78 documentation feedback 78 drive - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 80
options 25, 28 hardware options installation 28 health driver 49 health LEDs 11 HP contact information 64 HP Insight Diagnostics 51 HP Insight Remote Support software 52 HP Service Pack for ProLiant 45 HP Smart Update Manager overview 45 hpahcisr 72, 73, 74 I I/O module connectors 14 I/O module - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 81
(ROM-Based Setup Utility) 46, 47 RBSU configuration 46 rear panel components 13 redundant ROM 50 registering the server 27 regulatory compliance notices 56, 58, 61 release button 6 remote support and analysis tools 52 removing the access panel 20 requirements, airflow 23 requirements, power 24, 63 - HP ProLiant SL4545 | HP ProLiant SL4545 G7 Server Node User Guide - Page 82
V Version Control 53 VGA cabling 44 video connector 11 Vietnam compliance marking notice 60 W warnings 24 Windows 72, 73 Windows installation 72, 73 Index 82
HP ProLiant SL4545 G7 Server Node
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 683994-002
December 2012
Edition: 2