HP StorageWorks 8/20q HP StorageWorks 8/20q Fibre Channel Switch Command Line - Page 319
zoning merged, the contents of the merged zone set.
View all HP StorageWorks 8/20q manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 319 highlights
zoning merged Description Displays the contents of the merged zone set, or saves the merged zone set to the non-volatile zoning database. Authority Admin session for the capture operand. Syntax zoning merged capture Operands capture Saves the merged zone set to the non-volatile zoning database. You must enter the zoning save command to save your changes. If you omit this operand, this command displays the contents of the merged zone set. Examples The following is an example of the zoning merged command: 8/20q FC Switch #> zoning merged To permanently save the merged database locally, execute the 'zoning merged capture' command. To edit the merged database use the 'zoning edit merged' command. To remove the merged database use the 'zoning restore' command. Merged (unsaved) Zoning Information ZoneSet Zone ZoneMember ------- ---- ---------- ZS1 Z1 10:00:00:c0:dd:00:b9:f9 10:00:00:c0:dd:00:b9:fa Z2 10:00:00:c0:dd:00:b9:fb 10:00:00:c0:dd:00:b9:fc The following is an example of the zoning merged capture command: 8/20q FC Switch (admin) #> zoning merged capture This command will overwrite the configured zoning database in NVRAM. Please confirm (y/n): [n] y The merged zoning database has been saved. See also zoning configured, page 312 zoning edited, page 315 zoning list, page 318 8/20q Fibre Channel Switch Command Line Interface Guide 319