Page 26 highlights
Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A1005.003B) (Warning Debug logging filter level is set) Debug logging has been set using the set log level command. Confirm that you intended to do this. If not, use the set log level command to change the severity level to Info, Warn, or Critical. (A1005.003C) (User Port(s) port_numbers, isolated, lost steering path, administering them to state DOWNED.) The ports required for steering the user ports have failed. Contact your authorized maintenance provider. (A1005.003E) (Warning, port(s) port_numbers configured ONLINE, but remain DOWN after NDCLA.) Ports that were down before a non-disruptive code load and activation remain down. This message serves as a reminder because the alarm log is cleared during the non-disruptive code load and activation. None (A1005.003F) (Badly formatted SML Notification Ack session session_ID string - string) The switch sent a notification that was not formatted correctly; there may be a resource problem on the switch. If this is a recurring message, contact your authorized maintenance provider. (A1005.0040) (Unsupported SFP within port.) An unsupported small form-factor pluggable (SFP) transceiver was installed in the port. Replace the transceiver. (A1005.0041) (Setting port admin state DOWN due to POST failure) The port failed the power-on self test and has been disabled. Contact your authorized maintenance provider. (A1005.0042) (Target device port_address attached to port port_number with IOStreamGuard Enabled) Target device is attached to the port with IOStreamGuard enabled. Disable IOStreamGuard on the port. (A1005.0045) (Configured port data conflicting within hardware capabilities) Configured port settings conflict with the hardware capabilities of the port. The port is down. Reconfigure the port to be compatible with the port hardware. (A1005.004B) (The switch was reset due to firmware upgrade issues) After a firmware upgrade, the cyclic redundancy check (CRC) did not match what was expected. It is likely that licenses were updated on the switch while running older firmware. Check your license configuration for changes. (A1005.004E) (Attempts to login backend switch fail because backend switch does not support NPIV.) The backend fabric switch does not support N_Port ID Virtualization (NPIV), which in turn brings down the TF_Port. Ensure that the backend fabric switch supports NPIV. 26