HP StorageWorks SN6000 HP StorageWorks 8/20q and SN6000 Fibre Channel Switch e - Page 37
Load and Activation NDCLA, Power-on Self Test POST.
![]() |
View all HP StorageWorks SN6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A3003.0002) (POST detected a fatal error the last time it ran and will be re-executed.) A fatal hardware error was discovered from the previous Power-on Self Test (POST). This switch is not currently operational. Enter the show post log command to investigate. (A3004.0001) (Non-fatal hardware error detected. Use 'show post log' for more info) A non-fatal hardware error was discovered during the Power-on Self Test (POST) phase of startup. Enter the show post log command to investigate. (A3005.0001-000C) (value voltage sensor shows valueV - ALARM SET) A switch voltage sensor is experiencing an out-of-range voltage condition. Contact your authorized maintenance provider. (A3006.0001-000C) (value voltage sensor shows valueV - ALARM SET) An out-of-range voltage condition has occurred. Contact your authorized maintenance provider. (A3007.0001-000C) (value voltage sensor shows valueV - ALARM CLEAR) The out-of-range voltage condition has cleared. None (A3008.0000) (The configuration area was damaged or a Remake Filesystem was performed from PROM mode. You must perform a 'config restore' to clear this error.) The configuration area was damaged or a Remake Filesystem was performed from Maintenance mode. Enter the config restore command to clear the error. If this does not correct the problem, contact your authorized maintenance provider. (A4000.0001) (threshold of value hit rising trigger trigger_number in value second window on port port_number ALARM SET The switch exceeded the specified threshold for the rising trigger in the specified sample window. Investigate the specified port for problems, or adjust the rising trigger or sample window. (A6000.0002) (Configured port speed for port port_number not compatible with media.) The transceiver in the named port is not capable of transmitting at the configured port speed. Reconfigure the port speed or replace the transceiver. (A6001.0001) (cmon: insufficient memory) The hotreset command has failed due to insufficient memory on the switch. The switch has been returned to its state before the hotreset command was entered. If acceptable, enter the reset switch command to reboot the switch. Contact technical support if a non-disruptive code load and activation is required. (A6001.0003) (cmon: switch failed NDCLA) The Non-Disruptive Code Load and Activation (NDCLA) has failed. The switch has performed a hard reset. None HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 37
![](/manual_guide/products/hewlettpackard-ak241a-hp-storageworks-820q-sn6000-fibre-channel-switch-event-message-reference-guide-56970264-2010-d1b79f3/37.png)