Page 36 highlights
Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A1007.0036) (Port taken offline due to port binding failure following configuration change.) A configuration change was made to the port binding list such that the device(s) on the port were no longer allowed to be logged in. Add the devices to the port binding list. (A1007.0037) (Device device_wwn failed port binding) A switch device attempted to login as an inter-switch link (ISL), but that device was not configured in the port binding list for the specified port. Add the device to the port binding list. (A1007.0038) (Device device_wwn failed switch binding) A switch device attempted to login as an inter-switch link (ISL), but that device was not configured in the switch binding list. Add the device to the switch binding list. (A1007.0039) (Ignoring RADIUS Server server, no shared secret configured) An attempt was made to authenticate a switch login through a Remote Authentication Dial In User Service (RADIUS) server, but no shared secret exists. Configure a shared secret. (A1007.003A) (Using local user authentication. No radius servers configured for user authentication) A Remote Authentication Dial In User Service (RADIUS) configuration was set to authenticate user accounts through a RADIUS server, but no RADIUS server was configured. User accounts will be authenticated by the switch. Correct the user authentication order or configure a RADIUS server. (A3000.0001) (Temp overheat, sensor_name sensor reads value C ALARM SET) The chassis temperature has reached a failure threshold. Check air flow, fan operation, and ambient temperature. If the problem cannot be corrected, power down the switch. (A3001.0001) (Temp overwarm, sensor_name sensor reads value C ALARM SET) The chassis temperature has Check air flow, fan operation, reached a warning threshold. and ambient temperature. (A3002.0001) (sensor name sensor has returned to normal range - ALARM CLEARED) The chassis temperature has returned to the normal range and the alarm condition has been cleared. None (A3003.0001) (IOn) (Hardware error detected. Use 'show switch' for more info.) A fatal hardware error was discovered during the Power-on Self Test (POST) phase of startup. This switch is not currently operational. Enter the show post log command to investigate. 36