HP Vectra VEi8 HP Vectra VEi8, Technical Reference Manual (Product Description - Page 12
Environmental Specifications, Environmental Specifications System Processing Unit, with Hard Disk
View all HP Vectra VEi8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
NOTE 1 System Overview Specifications The power supply delivers 720mA at the V standby level. This extra current is required by the 100TX hardware layer so it can perform a remote power-on when a magic frame is received. An older power supply should not be used for a repair. When the PC is turned off with the power button on the front panel, the power consumption falls below 5 Watts, but is not zero. The special on/off method used by this PC extends the lifetime of the power supply. To reach zero power consumption in "off" mode, either unplug the PC from the power outlet or use a power block with a switch. If the PC is turned off, the time settings are maintained by the battery indefinitely (until the battery runs out of power). Environmental Specifications Environmental Specifications (System Processing Unit, with Hard Disk) Operating Temperature +5°C to +35°C (+ 41°F to 95° F) Storage Temperature -40°C to +70°C (-40°F to +158°F) Operating Humidity 15% to 80% (relative) Storage Humidity 8% to 85% (relative), non-condensing at 40°C (104°F) Acoustic noise emission: Operating Altitude (as defined ISO 7779) Typical sound level (LwA) ≤ 39 db (operating) 10000 ft (3100m) max Storage Altitude 15000ft (4600m) max Operating temperature and humidity ranges may vary depending upon the mass storage devices installed. High humidity levels can cause improper operation of disk drives. Low humidity levels can aggravate static electricity problems and cause excessive wear of the disk surface. 12