12.12 Idle Immediate (E1h/95h) Table 98: Idle Immediate command (E1h/95h) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature Sector Count Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D - - - - Command 1 1 1 0 0 0 0 1 76 CRC UNC 00 Error Register 54 3 2 1 0 0 IDN 0 ABT T0N AMN 00 0 V 0 0 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status see below Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 V0V - 0 - V The Idle Immediate command causes the device to enter Performance Idle mode. The device is spun up to operating speed. If the device is already spinning, the spin up sequence is not executed. During Idle mode the device is spinning and ready to respond to the host commands immediately. The Idle Immediate command will not affect the auto power down time-out parameter. Deskstar 7K400 Hard Disk Drive Specification 138