Hitachi 7K400 Specifications - Page 257
Write Stream DMA 3Ah
![]() |
UPC - 000053412935
View all Hitachi 7K400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 257 highlights
12.60 Write Stream DMA (3Ah) Table 180: Write Stream DMA Command (3Ah) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Low Data High Feature Current V V V V - V V V Previous V V V V V V V V Sector Count Current Previous V V V V V V V V V V V V V V V V Sector Number Current Previous V V V V V V V V V V V V V V V V Cylinder Current Low Previous V V V V V V V V V V V V V V V V Cylinder Current High Previous V V V V V V V V V V V V V V V V Device/Head - 1 - D - - - - Command 0 0 1 1 0 1 0 0 76 CRC UNC VV Error Register 54 3 2 1 0 0 IDN 0 ABT T0N AMN 0V 0 V 0 V Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Low Data High Error See below Sector HOB=0 Count HOB=1 Sector HOB=0 Number HOB=1 Cylinder HOB=0 Low HOB=1 Cylinder HOB=0 High HOB=1 Device/Head Status V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V See below ... Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 VVV - 0 - V The Write Stream DMA command allows the host to write data using the DMA data transfer protocol. This command allows for the host to specify to the device that additional actions need to be performed prior to the completion of the command if the required bits are set. If the Write Continuous bit is set to one, the device shall not stop execution of the command due to errors. If the WC bit is set to one and errors occur in the transfer or writing of the data, the device shall continue to transfer the amount of data requested and then provide ending status with the BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and the type of error, ICRC, IDNF, or ABRT, reported in the error log. If the WC bit is set to one and the Command Completion Time Limit expires, the device shall stop execution of the command and provide ending status with BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and report the fact that the Command Completion Time Limit expired by setting the CCTO bit in the error log to one, In all cases, the device shall attempt to transfer the amount of data requested within the Command Completion Time Limit event if some data transferred is in error. Output Parameters To The Device Feature Current URG (bit7) URG specifies an urgent transfer request. The Urgent bit specifies that the command should be completed in the minimum possible time by the device and shall be completed within the specified Command Completion Time Limit. Deskstar 7K400 Hard Disk Drive Specification 243
![](/manual_guide/products/hitachi-7k400-specifications-548f643/257.png)