English SERVICE AND REPAIRS WARNING ● Only service personnel trained by Hitachi, distributor or employer shall repair the Nailer. ● Use only parts supplied or recommended by Hitachi for repair. All quality Nailers will eventually require servicing or replacement of parts because of wear from normal use. NOTE: Specifications are subject to change without any obligation on the part of HITACHI. Maintenance chart ACTION WHY HOW Drain air line filter daily. Prevent accumulation of moisture and dirt. Open manual petcock. Keep lubricator filled. Keep the Nailer lubricated. Fill with Hitachi pneumatic tool lubricant. Clean filter element - then Prevent clogging of filter blow air through filter in with dirt. direction opposite to normal flow. Follow manufacturer's instructions. Clean magazine and feeder Prevent a jam. mechanism. Blow clean daily. Keep push lever working Promote operator safety and Blow clean daily. properly. efficient Nailer operation. Lubricate the Nailer after Extend the Nailer life. nailing. Supply 5 - 10 drops of lubricant into the Nailer. Drain air compressor. Keep the Nailer operated properly. Open petcock on air compressor tank. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

English
26
SERVICE AND REPAIRS
Only service personnel trained by Hitachi, distributor or em-
ployer shall repair the Nailer.
Use only parts supplied or recommended by Hitachi for repair.
All quality Nailers will eventually require servicing or replacement of parts because of wear
from normal use.
NOTE:
Specifications are subject to change without any obligation on the part of HITACHI.
WARNING
Maintenance chart
ACTION
WHY
HOW
Drain air line filter daily.
Prevent accumulation of
Open manual petcock.
moisture and dirt.
Keep lubricator filled.
Keep the Nailer
Fill with Hitachi pneumatic
lubricated.
tool lubricant.
Clean filter element — then
Prevent clogging of filter
Follow manufacturer’s
blow air through filter in
with dirt.
instructions.
direction opposite to
normal flow.
Clean magazine and feeder
Prevent a jam.
Blow clean daily.
mechanism.
Keep push lever working
Promote operator safety and
Blow clean daily.
properly.
efficient Nailer operation.
Lubricate the Nailer after
Extend the Nailer life.
Supply 5 – 10 drops of
nailing.
lubricant into the Nailer.
Drain air compressor.
Keep the Nailer operated
Open petcock on air
properly.