Honeywell TB7100A1000 Installation Instructions - Page 11
Tb7100a1000 Multipro™ Multispeed And Multipurpose Thermostat - how to unlock
View all Honeywell TB7100A1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 4. Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name 0349 Auto Fan Reset Default Setting All Settings 0 0-Inactive 1-Reset back to Auto after 2 hours 2-Reset back to Auto after 4 hours 0535 0540 Temporary 3 Occupied Duration Limit Number of Periods 4 0-12 hours 2-2 Periods 4-4 Periods 0580 Minimum 5 Compressor Off Time 0600 0610 0640 0650 0660 0670 Heat Temperature 90 Range Stops Cool Temperature 50 Range Stops Clock Format 12 Extended Fan-on 0 time Heat Extended Fan-on 0 time Cool Keypad Lockout 0 0680 Temperature 2 Control Heat 0685 Recovery Heat 5 Ramp Rate 0690 Temperature 2 Control Cool 0695 Recovery Cool 3 Ramp Rate 0-Off 2-2 minutes 3-3 minutes 4-4 minutes 5-5 minutes 40 to 90°F (4 to 32°C) 50 to 99°F (10 to 37°C) 12-12 Hour 24-24 Hour 0-Off 90-90 seconds 0-Off 40-40 seconds 0-Unlocked 1-Partial Lockout 1 2-Partial Lockout 2 3-Partial Lockout 3 4-Fully Locked 1-Less Aggressive 2-Standard 3-More Aggressive 0-20°F/hour 1-Less Aggressive 2-Standard 3-More Aggressive 0-20°F/hour Notes The timer will be set after the user selects the constant fan speed. Fan will be set to Auto automatically when time out. The start time is calculated after initial call for heat/cool is satisfied, then 2 hour timing begins. The timer will be set after the user selects the constant fan speed. Fan will be set to Auto automatically when time out. The start time is calculated after initial call for heat/cool is satisfied, then 4 hour timing begins. Only available for fan coil or PTAC applications. 0 means no limit. Does not appear if Non-programmable is chosen (ISU 0160). Applies to all days of the week. If 2 is selected the Cancel Period option will not appear on the display. Only shown if system has cool stages in CNV, Heat Pump, PTAC (ISU 0170). Only shown if system has heat stages (ISU 0170). Only shown if system has cool stages (ISU 0170). Not displayed if fan set to fossil or cool only systems (ISU 0170) Only shown if system has cool stages. (ISU 0170) Unlocked: All functions accessible. Partial 1: Locks out schedule and system changes. Partial 2: Locks out schedule, system, and fan changes. Partial 3: Locks out schedule, system, fan, and up/ down arrow changes. Full: Entire interface locked/non-functional. Only shown if system has heat stages (ISU 0170). Only integral gains are affected by this setting. The setting affects control operation in all control regimes (not just recovery or setpoint change). Only shown if system has heat stages (ISU 0170). 0 disables the ramped recovery (step setpoint change at period start time). Only shown if system has cool stages (ISU 0170). Only integral gains are affected by this setting. The setting affects control operation in all control regimes (not just recovery or setpoint change). Only shown if system has cool stages (ISU 0170). 0 disables the ramped recovery (step setpoint change at the period start time). 11 62-0273-05