INSTALLATION INSTRUCTIONS Gas models - U.S. and Canada A 120-volt, 60Hz AC approved electrical service, with a 15 ampere fuse or circuit breaker is required. Electric models - U.S. only The dryers require a 120/240 volt, 60Hz AC approved electrical service. The electric service requirements can be found on the data label located behind the door. A 30-ampere fuse or circuit breaker on both sides of the line is required. • If you use a power cord, you should plug the cord into a 30-ampere receptacle. • A power cord is NOT provided with U.S. electric model dryers. WARNING: RISK OF ELECTRIC SHOCK When local codes allow, the electrical supply of your dryer may be connected by means of a new power supply cord kit, marked for use with a dryer, that is UL listed and rated at a minimum of 120/240 volts, 30-ampere with three No. 10 copper wire conductors terminated with closed loop terminals, open-end spade lugs with turned up ends, or with tinned leads. • Do not reuse a power supply cord from an old dryer. The power cord electric supply wiring must be retained at the dryer cabinet with a suitable UL-listed strain relief. • Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. (Use a four-prong plug for four-wire receptacles, NEMA type 14-30R.) Electric models - Canada only You need a 120/240 volt, 60Hz AC approved electrical service fused through a 30-ampere fuse or circuit breaker on both sides of the line. All Canadian models are shipped with the power cord attached. The power cord should be plugged into a 30-ampere receptacle. Power outlet types Three-wire outlet (10-30R) Four-wire outlet (14-30R) Using a three-wire outlet If your outlet is a three-wire (three-prong) outlet, choose a three-wire power supply cord with ring or spade terminals and UL listed strain relief. The three-wire power supply cord must: • Be at least 4 ft. (1.22 m) long. • Have three 10-gauge solid copper wires. • Match a three-wire outlet of NEMA Type 10-30R. See Step-by-step instructions on page 22 for instructions on how to connect a power cord to your dryer. 18 www.insigniaproducts.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

18
www.insigniaproducts.com
INSTALLATION INSTRUCTIONS
Gas models - U.S. and Canada
A 120-volt, 60Hz AC approved electrical service, with a 15 ampere fuse or circuit
breaker is required.
Electric models - U.S. only
The dryers require a 120/240 volt, 60Hz AC approved electrical service. The electric
service requirements can be found on the data label located behind the door. A
30-ampere fuse or circuit breaker on both sides of the line is required.
If you use a power cord, you should plug the cord into a 30-ampere receptacle.
A power cord is NOT provided with U.S. electric model dryers.
Electric models - Canada only
You need a 120/240 volt, 60Hz AC approved electrical service fused through a
30-ampere fuse or circuit breaker on both sides of the line.
All Canadian models are shipped with the power cord attached. The power cord
should be plugged into a 30-ampere receptacle.
Power outlet types
Using a three-wire outlet
If your outlet is a three-wire (three-prong) outlet, choose a three-wire power
supply cord with ring or spade terminals and UL listed strain relief. The three-wire
power supply cord must:
Be at least 4 ft. (1.22 m) long.
Have three 10-gauge solid copper wires.
Match a three-wire outlet of NEMA Type 10-30R.
See Step-by-step instructions
on page 22
for instructions on how to connect a
power cord to your dryer.
WARNING: RISK OF ELECTRIC SHOCK
When local codes allow, the electrical supply of your dryer may be connected
by means of a new power supply cord kit, marked for use with a dryer, that is UL
listed and rated at a minimum of 120/240 volts, 30-ampere with three No. 10
copper wire conductors terminated with closed loop terminals, open-end
spade lugs with turned up ends, or with tinned leads.
Do not reuse a power supply cord from an old dryer. The power cord electric
supply wiring must be retained at the dryer cabinet with a suitable UL-listed
strain relief.
Grounding through the neutral conductor is prohibited for (1) new
branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and
(4) areas where local codes prohibit grounding through the neutral
conductor. (Use a four-prong plug for four-wire receptacles, NEMA type
14-30R.)
Three-wire outlet (10-30R)
Four-wire outlet (14-30R)