Intel SC5300BD2 Product Specification - Page 60

SCSI Backplane Status LEDs.

Page 60 highlights

Intel® Server Chassis SC5300 5U Kit TPS defined by the firmware, is detected. Hard Disk Drive Bays Drive 1 2 3 4 5 (6 HDD only) 6 (6 HDD only) Table 34. Hard Drive Activity LED HSBP LED Activated Drive 0 - Conn 2 Drive 1 - Conn 3 Drive 2 - Conn 4 Drive 3 - Conn 5 Drive 4 - Conn 6 Drive 5 - Conn 7 4 HDD Bay LED Designator D1 D2 D3 D4 none 6 HDD Bay LED Designator D1 D2 D3 D4 D5 Fault LED Color Yellow Yellow Yellow Yellow Yellow None D6 Yellow Activity LED Color Green Green Green Green Green Green The hot-swap controller (HSC) is responsible for turning the drive fault LEDs on or off according to the states specified via commands received from SAF-TE and the IMB. The drive fault LEDs are yellow and indicate failure status for each drive. The LEDs are physically located on the LVD SCSI backplane. The LEDs are 4-terminal dual-color (yellow and green) and are physically located on the backplane. 5.1.12 SCSI Backplane Status LEDs. Each SCSI backplane has two status LEDs used to indicate system fail or system alarm. These LED's are located on the power connector side of the SCSI backplane and are visible from the interior of the chassis. Table 35. SCSI Backplane LED Back plane 4 HDD 4 DD 6 HDD 6 HDD LED Designator Signal Name D5 SYS_FAIL D6 SYS_ALARM D7 SYS_FAIL D8 SYS_ALARM The following are isometric views of the SCSI backplane assemblies. Revision 1.31 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

Intel® Server Chassis SC5300 5U Kit TPS
Hard Disk Drive Bays
Revision 1.31
59
defined by the firmware, is detected.
Table 34.
Hard Drive Activity LED
Drive
HSBP LED
Activated
4 HDD Bay
LED
Designator
6 HDD Bay
LED
Designator
Fault
LED
Color
Activity
LED
Color
1
Drive 0
- Conn 2
D1
D1
Yellow
Green
2
Drive 1 – Conn 3
D2
D2
Yellow
Green
3
Drive 2 – Conn 4
D3
D3
Yellow
Green
4
Drive 3 – Conn 5
D4
D4
Yellow
Green
5 (6 HDD
only)
Drive 4 – Conn 6
none
D5
Yellow
Green
6 (6 HDD
only)
Drive 5 – Conn 7
None
D6
Yellow
Green
The hot-swap controller (HSC) is responsible for turning the drive fault LEDs on or off according
to the states specified via commands received from SAF-TE and the IMB.
The drive fault LEDs
are yellow and indicate failure status for each drive.
The LEDs are physically located on the
LVD SCSI backplane.
The LEDs are 4-terminal dual-color (yellow and green) and are physically located on the
backplane.
5.1.12
SCSI Backplane Status LEDs.
Each SCSI backplane has two status LEDs used to indicate system fail or system alarm. These
LED’s are located on the power connector side of the SCSI backplane and are visible from the
interior of the chassis.
Table 35.
SCSI Backplane LED
Back plane
LED Designator
Signal Name
4 HDD
D5
SYS_FAIL
4 DD
D6
SYS_ALARM
6 HDD
D7
SYS_FAIL
6 HDD
D8
SYS_ALARM
The following are isometric views of the SCSI backplane assemblies.