Intel SR1530HAHLX User Guide - Page 111

Replacing the PCI Cooling Fan SR1530AH/SR1530AHLX

Page 111 highlights

Replacing the PCI Cooling Fan (SR1530AH/SR1530AHLX) Caution: The PCI cooling fan is NOT hot swappable. Before removing or replacing the PCI cooling fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information" on page iii. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 28. 4. Disconnect the fan cable from the server board. See letter "A" in the figure below. A AF001176 Figure 82. Disconnecting the PCI Cooling Fan (SR1530AH/SR1530AHLX) 5. Lift the fan from the system. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

Intel
®
Server System SR1530AH / SR1530AHLX / SR1530HAHLX
89
Replacing the PCI Cooling Fan (SR1530AH/SR1530AHLX)
Caution:
The PCI cooling fan is NOT hot swappable. Before removing or replacing the PCI cooling
fan, you must first take the server out of service, turn off all peripheral devices connected
to the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
1.
Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the server system cover. For instructions, see
“Removing the Server
System Cover” on page 28
.
4.
Disconnect the fan cable from the server board. See letter “A” in the figure below.
Figure 82. Disconnecting the PCI Cooling Fan (SR1530AH/SR1530AHLX)
5.
Lift the fan from the system.
A
AF001176