Intel SR1530HAHLX User Guide - Page 76
Removing a Slimline Optical Drive
![]() |
View all Intel SR1530HAHLX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Removing a Slimline Optical Drive 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information" on page iii. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 28. 4. Remove the bezel if it is installed. For instructions, see "Removing the Front Bezel" on page 26. 5. SR1530AH/SR1530AHLX: Note the orientation of the PCI cooling fan that is located behind the optical drive bay, then lift the fan from the mounting pegs. It is not necessary to disconnect the fan cable. See letter "A" in Figure 48. A AF001208 Figure 48. Lifting PCI Cooling Fan from Mounting Pegs (SR1530AH/ SR1530AHLX) 6. Disconnect the optical drive power and data cables. See letters "A" and "B" in Figure 49. 7. Remove the screw that holds the optical drive bracket to the server chassis. See letter "C" in the figure below. Save this screw. You will reinstall it later. 8. Slide the optical drive out through the front of the system. See letter "D" in the figure. 54 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
![](/manual_guide/products/intel-sr1530ah-user-guide-11ce3bf/76.png)