Intel SR1550AL User Guide - Page 54

Installing and Removing a Hot-swap Hard Drive

Page 54 highlights

4. Reinstall and reconnect any parts you removed or disconnected to reach the processor sockets. 5. Replace the server's cover and reconnect the AC power cord. See the documentation that came with your server chassis for instructions on installing the server's cover. Removing a Processor 1. Observe the safety and ESD precautions in "Safety Information". 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Remove the AC power cord from the server. 4. Remove the server's cover. See the documentation that came with your server chassis for instructions on removing the server's cover. 5. Unplug the processor fan cable from the server board. 6. Loosen the four captive screws on the corners of the heat sink. 7. Twist the heat sink slightly to break the seal between the heat sink and the processor. 8. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force the heat sink from the processor. Doing so could damage the processor. 9. Lift the processor lever. 10. Raise the CPU load plate. 11. Remove the processor. 12. If installing a replacement processor, see "Installing the Processor". Otherwise, install the protective socket cover over the empty processor socket and reinstall the chassis cover. 13. Plug all peripheral devices and the AC power cable into the server. Installing and Removing a Hot-swap Hard Drive Up to six hot-swap SATA-150 drives or SAS drives can be installed. Cautions: If you install less than six drives or devices, empty drive bays must be occupied by carriers with baffles to maintain proper system cooling. To avoid possible damage to your server system, do not use older style drive carriers. Note: The server system does not support all hard drives. See "Server System References" for an Internet link to a list of supported hardware. 34 Intel® Server System SR1550AL/SR1550ALSAS User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

34
Intel
®
Server System SR1550AL/SR1550ALSAS User’s Guide
4.
Reinstall and reconnect any parts you removed or disconnected to reach the
processor sockets.
5.
Replace the server's cover and reconnect the AC power cord. See the
documentation that came with your server chassis for instructions on installing the
server's cover.
Removing a Processor
1.
Observe the safety and ESD precautions in
“Safety Information”
.
2.
Turn off all peripheral devices connected to the server. Turn off the server.
3.
Remove the AC power cord from the server.
4.
Remove the server's cover. See the documentation that came with your server
chassis for instructions on removing the server's cover.
5.
Unplug the processor fan cable from the server board.
6.
Loosen the four captive screws on the corners of the heat sink.
7.
Twist the heat sink slightly to break the seal between the heat sink and the
processor.
8.
Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink
again. Do not force the heat sink from the processor. Doing so could damage the
processor.
9.
Lift the processor lever.
10.
Raise the CPU load plate.
11.
Remove the processor.
12.
If installing a replacement processor, see
“Installing the Processor”
. Otherwise,
install the protective socket cover over the empty processor socket and reinstall the
chassis cover.
13.
Plug all peripheral devices and the AC power cable into the server.
Installing and Removing a Hot-swap Hard Drive
Up to six hot-swap SATA-150 drives or SAS drives can be installed.
Cautions:
If you install less than six drives or devices, empty drive bays must be occupied by
carriers with baffles to maintain proper system cooling.
To avoid possible damage to your server system, do not use older style drive carriers.
Note:
The server system does not support all hard drives. See
“Server System References“
for
an Internet link to a list of supported hardware.