Intermec CV30 Intermec Terminal Emulator (ITE) Programmer's Reference Manual - Page 109

Flow Control, Transmit Only supports XON/XOFF.

Page 109 highlights

Chapter 3 - Extended Commands Flow Control Control Character Sequence Example Descriptions Characters Description ^9F #P 5E72 010 08 PC character 0x9F Begin extended command for transmit only 19200 baud, even parity, 7 data bits, 2 stop bits Enable DTR Flow control Wait up to 8 seconds for return of DSR Data to send=0A=0D Sending string with CR, LF # Begin extended command terminating character ^9C ST character 0x9C The output stream takes the form of ASCII characters. For nondisplayable ASCII characters, you may insert the "=yy" characters, where "yy" is the hexadecimal representation of the output byte. The following table describes the line and columns where characters must appear, and their meanings. The symbol "b" indicates a 1-byte space. Control Character Sequence Method Column Description Character 2 Begin extended command. # 3 Transmit Only on P RS-232 Port command. 4 Speed (bits per second). 1=1200; 2=2400; 3=4800; 4=9600; 5=19200; 6=38400; 7=57600; 8=115200 5 Data parity. N=None; 0 (zero)=None; b=None; E=Even; O=Odd 6 7 8-9 10 11-12 Data bits. Stop bits. Reserved. XON/XOFF flow control. Flow control timeout value. 7=Seven; 8=Eight 1=One; 2=Two bb 0=Disable; 1=Enable XX=Number of seconds Transmit Only supports XON/XOFF. Intermec Terminal Emulator (ITE) Programmer's Reference Manual 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

Chapter 3 — Extended Commands
Intermec Terminal Emulator (ITE) Programmer’s Reference Manual
97
The output stream takes the form of ASCII characters. For nondisplayable ASCII
characters, you may insert the “=yy” characters, where “yy” is the hexadecimal
representation of the output byte.
The following table describes the line and columns where characters must appear,
and their meanings. The symbol “b
” indicates a 1-byte space.
Flow Control
Transmit Only supports XON/XOFF.
Control Character Sequence Example Descriptions
Characters
Description
^9F
PC character 0x9F
#P
Begin extended command for transmit only
5E72
19200 baud, even parity, 7 data bits, 2 stop bits
010
Enable DTR Flow control
08
Wait up to 8 seconds for return of DSR
Data to send=0A=0D
Sending string with CR, LF
#
Begin extended command terminating character
^9C
ST character 0x9C
Control Character Sequence Method
Column
Description
Character
2
Begin extended command.
#
3
Transmit Only on
RS-232 Port command.
P
4
Speed (bits per second).
1=1200; 2=2400; 3=4800; 4=9600; 5=19200;
6=38400; 7=57600; 8=115200
5
Data parity.
N=None; 0 (zero)=None; b
=None; E=Even; O=Odd
6
Data bits.
7=Seven; 8=Eight
7
Stop bits.
1=One; 2=Two
8-9
Reserved.
bb
10
XON/XOFF flow control.
0=Disable; 1=Enable
11-12
Flow control timeout value.
XX=Number of seconds