Intermec CV30 Intermec Terminal Emulator (ITE) Programmer's Reference Manual - Page 126

Interleaved 2 of 5, Return Codes for Scan Bar Code

Page 126 highlights

Chapter 3 - Extended Commands Interleaved 2 of 5 If Interleaved 2 of 5 is enabled, select the maximum and minimum lengths and the first and second fixed bar code lengths according to requirements. Refer to the manufacturer's bar code specifications for more information. Note: The symbol "b" indicates a 1-byte space. Interleaved 2 of 5 Character 29 30-31 32-33 34-35 36-37 Description 0=Interleaved 2 of 5 disabled 1=Interleaved 2 of 5 enabled b=No change from current setting XX=maximum length Interleaved 2 of 5 bb=No change from current setting XX=minimum length Interleaved 2 of 5 bb=No change from current setting XX=1st fixed length for Interleaved 2 of 5 Bar Code bb=No change from current setting XX=2nd fixed length for Interleaved 2 of 5 Bar Code bb=No change from current setting Return Codes for Scan Bar Code The Scan Bar Code Parameters return code is the status sent to the host computer; the code indicates if the extended command was successful. The computer returns data and the extended command's status to the host computer in the \\X format where X is the return code listed in the following chart. The computer simulates the [Enter] key to return a value to the host computer. If a hexadecimal number is entered incorrectly, the return code defaults to "0." Return Codes for Scan Bar Code Code 0 1 Z Description Good status, transaction complete Bad status, transaction incomplete Command not supported for this device 114 Intermec Terminal Emulator (ITE) Programmer's Reference Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

Chapter 3 — Extended Commands
114
Intermec Terminal Emulator (ITE) Programmer’s Reference Manual
Interleaved 2 of 5
If Interleaved 2 of 5 is enabled, select the maximum and minimum lengths and the
first and second fixed bar code lengths according to requirements. Refer to the
manufacturer's bar code specifications for more information.
Return Codes for Scan Bar Code
The Scan Bar Code Parameters return code is the status sent to the host computer;
the code indicates if the extended command was successful. The computer returns
data and the extended command's status to the host computer in the \\X<CR>
format where X is the return code listed in the following chart. The computer
simulates the [Enter] key to return a value to the host computer. If a hexadecimal
number is entered incorrectly, the return code defaults to “0.”
Note:
The symbol “b
” indicates a 1-byte space.
Interleaved 2 of 5
Character
Description
29
0=Interleaved 2 of 5 disabled
1=Interleaved 2 of 5 enabled
b
=No change from current setting
30-31
XX=maximum length Interleaved 2 of 5
bb
=No change from current setting
32-33
XX=minimum length Interleaved 2 of 5
bb
=No change from current setting
34-35
XX=1st fixed length for Interleaved 2 of 5 Bar Code
bb
=No change from current setting
36-37
XX=2nd fixed length for Interleaved 2 of 5 Bar Code
bb
=No change from current setting
Return Codes for Scan Bar Code
Code
Description
0
Good status, transaction complete
1
Bad status, transaction incomplete
Z
Command not supported for this device