Intermec CV30 Intermec Terminal Emulator (ITE) Programmer's Reference Manual - Page 122
Bar Code Length, UPC, UPC Command Characters
View all Intermec CV30 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
Chapter 3 - Extended Commands Bar Code Length Bar Code Length sets the minimum and maximum character lengths for all types of bar codes scanned. Setting the minimum and maximum values to their optimum can increase scanning performance. If the computer scans bar codes that are outside the minimum and maximum value, the computer ignores the bar code. Bar Code Length Column 7-8 9-10 Character and Description XX=Bar code length. Maximum length: 99. bb=1-byte spaces. No change from current setting. XX=Bar code length. Minimum length: 00. bb=1-byte spaces. No change from current setting. UPC Use the UPC command to select combinations of characters in this table. UPC Command Characters Expand UPC-E Character UPC-E # System 1 to UPC-A UPC-E # System 0 0 Disables all. 1 2 X 3 X 4 X 5 X 6 7 8 X 9 X 10 X 11 X 12 X X X X X X X X 13 X X 14 X X X 15 X X X b 1-byte space. No change from current setting. Add-ons UPC-A X X X X X X X X X X X X X X X X X X X X X X 110 Intermec Terminal Emulator (ITE) Programmer's Reference Manual