Adjusting T-Arm Sockets, ARMS
View all Invacare CLTD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
SECTION 5-ARMS Adjusting T-Arm Sockets NOTE: For this procedure, refer to FIGURE 5.7. NOTE: Perform this procedure if the T-Arm is too loose in the socket or does not easily slide UP and DOWN in the socket. 1. Remove the rear wheels from the wheelchair, if necessary. Refer to Installing/Removing Rear Wheels on page 58. 2. Loosen, but DO NOT remove the four hex screws and washers that secure T-Arm socket to T-Arm clamp. NOTE: The T-Arm socket will disassemble if the four hex screws and washers are removed. 3. Slide the T-Arm into the T-Arm socket until the locking lever is in the slot in the T-Arm socket and an audible "click" is heard. 4. Squeeze the T-Arm socket and the T-Arm clamp together until the socket is flush with the T-Arm. 5. While holding the T-Arm socket and the T-Arm clamp together, tighten the four hex screws and washers. Tighten securely. 6. Press IN on the locking lever and lift the T-Arm straight UP and out of the T-Arm socket. 7. Repeat STEPS 3-6, if necessary until the T-Arm slides in the T-Arm socket as desired. 8. If necessary, install rear wheels. Refer to Installing/Removing Rear Wheels on page 58. T-Arm Hex Screws and Washers T-Arm Clamp Hex Screws and Washers Slot Locking Lever T-Arm Socket FIGURE 5.7 Adjusting T-Arm Sockets Part No 1122134 45 Compass™SPT™