Setup About Connection Cables (Continued) DC 12 V or AC 24 V power supply cable Connect the power cord to the DC 12 V or the AC 24 V power supply. The unit is to be powered by a UL Listed Class 2 power supply only. (For USA and Canada) The AC 24 V and DC 12 V power supply shall conform to the following: UL Listed Class 2 power supply only, Class 2 not wet and Class 3 wet wiring (For USA) Isolated power supply only (For Europe) This installation shall be in accordance with the National Electrical Code, ANSI/NFPA 70. The following table shows the connection distances when 2-core VVF (vinyl-insulated vinyl sheath cables) are used. (Reference value) Conductor diameter Maximum connection distance: DC 12 V (not using heater) Maximum connection distance: AC 24 V (not using heater) Maximum connection distance: AC 24 V (using heater) Φ 1.0 mm (AWG 18) 50 m (160 ft) 130 m (420 ft) 40 m (130 ft) Φ 1.6 mm (AWG 14) 140 m (450 ft) 350 m (1100 ft) 120 m (390 ft) Φ 2.0 mm (AWG 12) 220 m (720 ft) 550 m (1800 ft) 180 m (590 ft) E-20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

About Connection Cables (Continued)
DC 12 V or AC 24 V power supply cable
Connect the power cord to the DC 12 V or the AC 24 V power supply.
The unit is to be powered by a UL Listed Class 2 power supply only.
(For USA and Canada)
The AC 24 V and DC 12 V power supply shall conform to the following:
UL Listed Class 2 power supply only,
Class 2 not wet and Class 3 wet wiring (For USA)
Isolated power supply only (For Europe)
This installation shall be in accordance with the National Electrical
Code, ANSI/NFPA 70.
The following table shows the connection distances when 2-core VVF
(vinyl-insulated vinyl sheath cables) are used. (Reference value)
Conductor
diameter
Maximum
connection
distance: DC 12 V
(not using heater)
Maximum
connection
distance: AC 24 V
(not using heater)
Maximum
connection
distance: AC 24 V
(using heater)
Φ
1.0 mm
(AWG 18)
50 m (160 ft)
130 m (420 ft)
40 m (130 ft)
Φ
1.6 mm
(AWG 14)
140 m (450 ft)
350 m (1100 ft)
120 m (390 ft)
Φ
2.0 mm
(AWG 12)
220 m (720 ft)
550 m (1800 ft)
180 m (590 ft)
Setup
E-20