Kenmore 5894 Use and Care Guide - Page 25
Model, P1KB2/PIRFKB2, Capacity, Gallons, Liters, without, Filter, Indicator, Light
UPC - 883049132563
View all Kenmore 5894 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Base Grille Water Filtration System Model P1KB2/PIRFKB2 Capacity 200 Gallons (757 Liters) without Filter Indicator Light Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of SLeyastde,mMetersctuerdy, aAntrdazcineert,ifiedBenzbeyneN,SFToInxtaeprnhaetnioen, al O-DagicahinlosrtobeNnSzeFn/AeN, SI CSytasntsd,ardTurb4i2ditfyo,r tAhsebersetdousc, tion of Lindane, Tetrachloroethylene, Endrin, Alachlor, Styrene, Chlorobenzene and Ethylbenzene. This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53. Substance Reduction Aesthetic Effects NSF Reduction Requirements Average Influent Influent Challenge Concentration Maximum Effluent Minimum % Reduction Average % Reduction Chlorine Taste/Odor Particulate Class I* Contaminant Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 Mercury: @ pH 6.5 Mercury: @ pH 8.5 Benzene O-Dichlorobenzene 50% reduction 85% reduction NSF Reduction Requirements 0.010 mg/L 0.010 mg/L 0.002 mg/L 0.002 mg/L 0.005 mg/L 0.6 mg/L 2.10 mg/L 21000000#/mL Average Influent 150 ug/L 160 ug/L 5.8 ug/L 6.1 ug/L 15 ug/L 1900 ug/L 2.0 mg/L + 10% At least 10,000 particles/mL Influent Challenge Concentration 0.15 mg/L + 10% 0.15 mg/L _+10% 0.006 mg/L + 10% 0.006 mg/L _+10% 0.015 mg/L _+10% 1.8 mg/L _+10% 0.05 mg/L ** 140000 #/mL Maximum Effluent 1.0 ug/L 2.0 ug/L 0.3 ug/L 0.4 ug/L 0.5 ug/L 0.7 ug/L 97.6 99 Minimum % Reduction 99.3 98.7 94.9 93.4 96.7 99.9 97.6 99.5 Average % Reduction 99.3 99.3 96.6 95.3 96.7 99.9 Toxaphene Atrazine Asbestos 0.003 mg/L 14 ug/L 0.015 mg/L _+10% 1.0 ug/L 91.5 92.8 0.003 mg/L 9.0 ug/L 0.009 mg/L _+10% 0.5 ug/L 94.5 94.5 99% 130 MFL 107to 108fibers/U t 0.17 MFL 99 99 Live Cysts _ Turbidity >99.95% 0.5 NTU 96,000/L 12 NTU 50,000/L min. 11 _+1 NTU 1/U 0.4 NTU 99.99 96.7 99.99 98.5 Alachlor Endrin Ethylbenzene 0.002 mg/L 41 ug/L 0.04 mg/L _+10% 1.0 ug/L 97.6 97.6 0.002 mg/L 5.9 ug/L 0.006 mg/L _+10% 0.2 ug/L 96.5 96.6 0.7 mg/L 2100 ug/L 2.1 mg/L _+10% 0.5 ug/L 99.9 99.9 Lindane 0.0002 mg/L 1.9 ug/L 0.002 mg/L _+10% 0.02 ug/L 99 99 Chlorobenzene 0.1 mg/L 2100 ug/L 2.0 mg/L _+10% 1.1 ug/L 99.9 99.9 Tetrachloroethylene 0.005 mg/L 14 ug/L 0.015 mg/L _+10% 0.5 ug/L 96 96.4 Styrene 0.1 mg/L 2200 ug/L 2.0 mg/L _+10% ND (0.5) 99.9 99.9 Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters). • It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. • Refer to the "Warranty" section for the Manufacturer's name, address and telephone number. • Refer to the "Warranty" section for the Manufacturer's limited • Model P1KB2: Change the water filter cartridge every 6 months. If the water flow to the water dispenser or ice maker decreases noticeably before 6 months have passed, replace the water filter cartridge more often. Use replacement cartridge P1 RFKB2, part #9030. 2008 suggested retail price of $59.99 U.S.A./S71.99 Canada. warranty. Application Water Supply Water Pressure Guidelines/Water Supply Parameters City or Well 30 - 120 psi (207 - 827 kPa) Prices are subject to change without notice. Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C) • These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. Service Flow Rate 0.5 gpm (1.9 L/min) @ 60 psi • The product is for cold water use only. • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. *Class I particle size: >0.5 to