Kenmore 7800 Installation Instructions - Page 5

Use a new CSA International

Page 5 highlights

Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. IMPORTANT: The range must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate. A copy of the above code standards can be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 • A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided. • Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded. • The wiring diagram is located on the back of the range in a clear plastic bag. Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. if connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Observe all governing codes and ordinances. IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest edition. IMPORTANT: Leak testing of the range must be conducted according to the manufacturers instructions. Type of Gas Natural gas: This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. • This range is factory set for use with Natural gas. See "Gas Conversions" section. The model/serial rating plate located behind the control panel has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier. LP gas conversion: Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See "Gas Conversions" section. Gas Supply Line • Provide a gas supply line of 3A" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON _t tape. With LP gas, piping or tubing size can be r/2" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. t®TEFLON is a registered trademark of E.I, Du Pont De Nemours and Company.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Electrical
Shock
Hazard
Plug into
a
grounded
3 prong
outlet.
Do not remove ground
prong.
Do not use
an
adapter.
Do not use
an
extension
cord.
Failure to
follow
these instructions
can result in death,
fire,
or
electrical
shock.
IMPORTANT:
The range must be electrically
grounded
in
accordance
with local codes and ordinances,
or in the absence
of local codes,
with the National Electrical
Code, ANSI/NFPA
70
or Canadian
Electrical
Code, CSA C22.1.
If codes
permit
and a separate
ground
wire is used, it is
recommended
that a qualified
electrical
installer determine
that
the ground
path is adequate.
A copy
of the above code standards
can be obtained
from:
National
Fire Protection
Association
One Batterymarch
Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland,
OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp fused,
electrical
circuit
is
required.
A time-delay
fuse or circuit
breaker
is also
recommended.
It is recommended
that a separate
circuit
serving only this range be provided.
Electronic
ignition systems
operate within wide voltage limits,
but proper
grounding
and polarity
are necessary.
Check that
the outlet provides
120-volt
power and is correctly
grounded.
The wiring
diagram
is located
on the back
of the range in a
clear plastic
bag.
Explosion
Hazard
Use a new CSA International
approved
gas
supply
line.
Install
a
shut-off
valve.
Securely
tighten
all gas connections.
if
connected
to LP, have a qualified
person
make
sure
gas
pressure
does
not
exceed
14" (36 cm) water
column.
Examples
of
a
qualified
person
include:
licensed
heating
personnel,
authorized
gas company
personnel,
and
authorized
service
personnel.
Failure
to
do so
can result
in death,
explosion,
or
fire.
Observe all governing
codes and ordinances.
IMPORTANT:
This installation
must conform
with
all local codes
and ordinances.
In the absence of local codes,
installation
must
conform
with American
National Standard,
National
Fuel Gas
Code ANSI
Z223.1
- latest edition
or CAN/CGA
B149 - latest
edition.
IMPORTANT:
Leak testing
of the range must be conducted
according
to the manufacturers
instructions.
Type of Gas
Natural
gas:
This range is design-certified
by CSA International
for use with
Natural gas or, after proper conversion,
for use with
LP gas.
This range is factory
set for use with
Natural gas. See "Gas
Conversions"
section.
The model/serial
rating plate located
behind
the control
panel has information
on the types
of gas
that can be used. If the types
of gas listed do not include
the
type of gas available,
check
with the local gas supplier.
LP gas conversion:
Conversion
must be done by a qualified
service technician.
No attempt
shall be made to convert the appliance
from the gas
specified
on the model/serial
rating
plate for use with a different
gas without
consulting
the serving
gas supplier. See "Gas
Conversions"
section.
Gas
Supply
Line
Provide
a gas supply
line of 3A" (1.9 cm) rigid pipe to the
range location.
A smaller
size pipe on longer runs may result
in insufficient
gas supply.
Pipe-joint
compounds
that resist
the action of LP gas must be used. Do not use TEFLON _t
tape. With LP gas, piping
or tubing
size can be r/2" (1.3 cm)
minimum.
Usually, LP gas suppliers
determine
the size and
materials
used in the system.
t®TEFLON
is a registered
trademark
of E.I, Du Pont De Nemours
and Company.