1. Run some water from the hot and cold faucets to flush the water lines and remove particles that might clog up the water valve screens. C. Open the shutoff valve in the gas supply line. d. Test all connections by brushing on a soapy water solution. NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME. . Check inlet hoses to ensure the rubber washers are installed in each end. . Carefully connect the inlet hoses to the water valve (on the left side of the washer cabinet), tighten by hand, then tighten another 2/3 turn with pliers. . Form a " U " shape on the end of the drain hose with the hose pointed toward the drain. Place the formed end in a laundry tub or a standpipe and secure with a cable tie provided in the enclosure package. WATER WILL SYPHON FROM THE WASHER IF THEABOVE INSTRUCTIONS ARE NO T FOLLOWED. DO NOT CROSS THREAD OR -- OVERTIGHTEN THESECONNECTIONS. . Determine which water faucet is the HOT water faucet and carefully connect the bottom inlet hose to the HOT water faucet, tighten by hand, then tighten another 2/3 turn with pliers. Carefully connect the top inlet hose to the COLD water faucet, tighten by hand, then tighten another 2/3 turn with pliers. DO NOT CROSS THREAD OR -- OVERTIGHTEN THESE CONNECTIONS. Turn the water on and check for leaks at both connections. 5. Carefully move the laundry center to its final location. 6. To ensure the laundry center is level and solid on all four legs, tilt the laundry center forward so the rear legs are off the ground. Gently set the laundry center back down to allow the rear legs to self adjust. Placea level on top of the washer. Check it side to side, then front to back. Screw the front leveling legs up or down to ensure the laundry center is resting solid on all four legs (no rocking of the laundry center should exist). NOTE: Keep the leg extension at a minimum to prevent excessive vibration. Cable Tie - . Remove the two (2) screws securing the dryer front access panel to the dryer cabinet. Lift the panel until the tabs can be disengaged from the cabinet. Remove the panel and set aside. 7. GAS CONNECTION (Gas/aundry centers on/y) a. Remove the shipping cap from gas pipe at the rear of the dryer. NOTE: DO NOTconnect the laundry center to L R gas service without converting the gas valve. An LR conversion kit must be installed by a qualified gas technician. b. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from the gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer. Use a 1/2 inch (1.27 cm) to 3/8 inch (0.96 cm) reducer for the connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

1. Run some water from the hot and cold faucets to flush the
water
lines and remove particles that might
clog up the
water valve screens.
.
.
Check inlet hoses to ensure the rubber washers are installed
in each end.
Carefully connect the inlet hoses to the water valve (on the
left side of the washer cabinet), tighten by hand, then tighten
another 2/3 turn with pliers.
C.
d.
.
Open the shutoff valve in the gas supply line.
Test all connections by brushing on a soapy water solution.
NEVER TEST FOR
GAS
LEAKS
WITH
AN OPEN FLAME.
Form a " U " shape on the end of the drain hose with the
hose pointed toward
the drain. Place the formed
end in a
laundry
tub or a standpipe
and secure with
a cable tie
provided in the enclosure package.
WATERWILLSYPHON
FROM
THEWASHER
IF
THE
ABOVE
INSTRUCTIONS ARE NO
T FOLLOWED.
DO NOT
CROSS
THREAD
OR
--
OVERTIGHTEN THESE
CONNECTIONS.
.
Determine which water
faucet is the
HOT
water
faucet
and carefully
connect the bottom
inlet hose to the
HOT
water
faucet, tighten
by hand, then tighten
another 2/3
turn with pliers. Carefully connect the top inlet hose to the
COLD
water faucet, tighten by hand, then tighten another
2/3 turn with pliers.
DO NOT
CROSS
THREAD
OR
--
OVERTIGHTEN THESE
CONNECTIONS.
Turn the water on and check for leaks at both connections.
5. Carefully move the laundry center to its final location.
6. To ensure the laundry center is level and solid on all four
legs, tilt the laundry center forward
so the rear legs are off
the ground.
Gently set the laundry center back down to
allow the rear legs to self adjust. Placea level on top of the
washer. Check it side to side, then front
to back. Screw
the front
leveling legs up or down to ensure the laundry
center is resting solid on all four
legs (no rocking
of the
laundry center should exist).
NOTE:
Keep the leg extension at a minimum
to prevent
excessive vibration.
7.
GAS CONNECTION
(Gas/aundry
centers on/y)
a.
b.
Remove the shipping cap from gas pipe at the rear of the
dryer.
NOTE: DO NOTconnect
the laundry center to L R gas service
without converting the gas valve. An LR conversion kit must
be installed by a qualified gas technician.
Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved
pipe from the gas supply line to the 3/8 inch (0.96 cm) pipe
located on the back of the dryer. Use a 1/2 inch (1.27 cm)
to 3/8 inch (0.96 cm) reducer for the connection. Apply an
approved thread sealer that
is resistant to the corrosive
action of liquefied gases on all pipe connections.
Cable
Tie
-
.
Remove the two (2) screws securing the dryer front
access
panel to the dryer cabinet. Lift the panel until the tabs can
be disengaged from the cabinet. Remove the panel and set
aside.
10