2.2 Installation Procedures 2 5 Pull out the fixing plate [1] forward. 6 Holding the handles on the rear and front sides [2] of the fusing unit [1] by both hands, slide the fusing unit [1] forward to the position of arrow mark. Please be careful when working on the fusing unit; the unit is extremely hot. 7 Holding the handles on the rear and front sides [2] of the fusing unit [1] by both hands, remove the fusing unit [1]. Place the removed fusing unit on the flat surface. 8 Holding the handles on the front and rear sides [2] of Fus- ing Unit EF-103 [1] with both hands, set Fusing Unit EF103 [1] on the fixing position with arrow mark. NOTICE Make sure that the exit section is open before setting Fusing Unit EF-103 to the machine. When you try to set the fusing unit with the exit guide unit closed, the machine may be damaged. AccurioPress C3080/C3080P/C3070, AccurioPrint C3070L 2-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

AccurioPress C3080/C3080P/C3070, AccurioPrint C3070L
2-5
2.2
Installation Procedures
2
5
Pull out the fixing plate [1] forward.
6
Holding the handles on the rear and front sides [2] of the
fusing unit [1] by both hands, slide the fusing unit [1] for-
ward to the position of arrow mark.
Please be careful when working on the fusing unit; the unit
is extremely hot.
7
Holding the handles on the rear and front sides [2] of the
fusing unit [1] by both hands, remove the fusing unit [1].
Place the removed fusing unit on the flat surface.
8
Holding the handles on the front and rear sides [2] of Fus-
ing Unit EF-103 [1] with both hands, set Fusing Unit EF-
103 [1] on the fixing position with arrow mark.
NOTICE
Make sure that the exit section is open before setting Fus-
ing Unit EF-103 to the machine. When you try to set the
fusing unit with the exit guide unit closed, the machine may
be damaged.