Konica Minolta Kodak i1405 Setup Guide - Page 16

Multi-feed Detection options, Length Detection, Auto Set, Ultrasonic Detection, Sensitivity, Medium

Page 16 highlights

Multi-feed Detection options • Length Detection ⎯ enable or disable (the default) this option. If enabled, select the maximum length of the document that can be scanned without a multi-feed being detected. Length detection is used when scanning same-sized documents to check for overlap. For example, if you are scanning 8.5 x 11-inch (A4) documents in portrait mode, enter a value of 11.25 inches (28.57 cm) in the Maximum Length field. The maximum value is 13.99 inches (35.56 cm). • Auto Set: automatically sets the maximum length value to .50-inch (1.27 cm) greater than the length of the currently selected page size. Ultrasonic Detection - check this option to set multi-feed detection. • Sensitivity - controls how aggressively the scanner will work to determine if more than one document is fed into the transport. Multifeeds are triggered by detecting air gaps between documents. This allows multi-feed detection to be used with job sets containing documents with mixed thicknesses. - Low: the least aggressive setting and is less likely to detect labels, poor quality, thick or wrinkled documents as multi-fed documents. - Medium: use Medium sensitivity if your application has varying document thickness or labels attached to the document. Depending on the label material, most documents with labels should not be detected as a multi-fed document. - High: the most aggressive setting. This is a good setting to use if all documents are similar in thickness to 20-lb. Bond paper. • Action - select an option of how you want to the scanner to perform if it detects a multi-fed document. - Beep and Continue: if selected, the scanner will beep, display and log the condition but continue to operate. - End of Job: if selected, the scanner log the condition and stop the feeder and transport (the scanner will be disabled). • Alarm - select this option if you want the scanner to make a sound when a multi-feed is detected. You can click the Speaker icon to display the Open dialog box. From the Open dialog box, select the desired .wav file and click OK. A-61661 May 2010 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

A-61661 May 2010
15
Multi-feed Detection options
Length Detection
enable or disable (the default) this option. If
enabled, select the maximum length of the document that can be
scanned without a multi-feed being detected. Length detection is
used when scanning same-sized documents to check for overlap. For
example, if you are scanning 8.5 x 11-inch (A4) documents in portrait
mode, enter a value of 11.25 inches (28.57 cm) in the
Maximum
Length
field. The maximum value is 13.99 inches (35.56 cm).
Auto Set:
automatically sets the maximum length value to .50-inch
(1.27 cm) greater than the length of the currently selected page size.
Ultrasonic Detection
— check this option to set multi-feed detection.
Sensitivity
— controls how aggressively the scanner will work to
determine if more than one document is fed into the transport. Multi-
feeds are triggered by detecting air gaps between documents. This
allows multi-feed detection to be used with job sets containing
documents with mixed thicknesses.
-
Low
: the least aggressive setting and is less likely to detect
labels, poor quality, thick or wrinkled documents as multi-fed
documents.
-
Medium
: use Medium sensitivity if your application has varying
document thickness or labels attached to the document.
Depending on the label material, most documents with labels
should not be detected as a multi-fed document.
-
High
: the most aggressive setting. This is a good setting to use if
all documents are similar in thickness to 20-lb. Bond paper.
Action
— select an option of how you want to the scanner to perform
if it detects a multi-fed document.
-
Beep and Continue
: if selected, the scanner will beep, display
and log the condition but continue to operate.
-
End of Job
: if selected, the scanner log the condition and stop
the feeder and transport (the scanner will be disabled).
Alarm
— select this option if you want the scanner to make a sound
when a multi-feed is detected. You can click the
Speaker
icon to
display the Open dialog box. From the Open dialog box, select the
desired .wav file and click
OK
.