Lantronix XPort Pro LX6 xPort Pro Lx6 - User Guide - Page 30

To Con Tunnel Serial Settings, Using Web Manager, Using the CLI, Using XML, Packing Mode

Page 30 highlights

6: Line and Tunnel Settings Tunnel Serial Settings Line Settings Protocol DTR Table 6-3 Tunnel Serial Settings Description Line Settings information here is display only. Go to the section, To Configure Line Settings to modify these settings. Protocol information here is display only. Go to the section, To Configure Line Settings to modify these settings. Select the conditions in which the Data Terminal Ready (DTR) control signal on the serial line are asserted. Choices are:  Unasserted  TruPort = the DTR is asserted whenever either a connect or an accept mode tunnel connection is active with the Telnet Protocol RFC2217 saying that the remote DSR is asserted.  Asserted while connected = the DTR is asserted whenever either a connect or an accept mode tunnel connection is active.  Continuously asserted To Configure Tunnel Serial Settings Using Web Manager  To configure the Serial Settings for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Serial Settings. Using the CLI  To enter Tunnel 1 command level: enable -> tunnel 1 -> serial Using XML  Include in your file: Packing Mode With Packing, data from the serial Line is not sent over the network immediately. Instead, data is queued and sent in segments, when either the timeout or byte threshold is reached. Packing applies to both Accept and Connect Modes. Table 6-4 Tunnel Packing Mode Settings Tunnel Packing Mode Settings Mode Threshold Description Configure the Tunnel Packing Mode. Choices are:  Disable = Data not packed.  Timeout = data sent after timeout occurs.  Send Character = data sent when the Send Character is read on the Serial Line. Set the threshold (byte count). If the received serial data reaches this threshold, then the data will be sent on the network. Valid range is 100 to 1450 bytes. Default is 512. XPort® Pro Lx6 Embedded Device Server User Guide 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

6: Line and Tunnel Settings
XPort® Pro Lx6 Embedded Device Server User Guide
30
Table 6-3
Tunnel Serial Settings
To Configure Tunnel Serial Settings
Using Web Manager
To configure the Serial Settings for a specific tunnel, click
Tunnel
in the menu and select
Tunnel 1 -> Serial Settings
.
Using the CLI
To enter Tunnel 1 command level:
enable -> tunnel 1 -> serial
Using XML
Include in your file:
<configgroup name=”tunnel serial” instance=”1”>
Packing Mode
With Packing, data from the serial Line is not sent over the network immediately.
Instead, data is
queued and sent in segments, when either the timeout or byte threshold is reached.
Packing
applies to both Accept and Connect Modes.
Table 6-4
Tunnel Packing Mode Settings
Tunnel Serial
Settings
Description
Line Settings
Line Settings information here is display only.
Go to the section,
To Configure
Line Settings
to modify these settings.
Protocol
Protocol
information here is display only.
Go to the section,
To Configure
Line Settings
to modify these settings.
DTR
Select the conditions in which the Data Terminal Ready (DTR) control signal
on the serial line are asserted.
Choices are:
Unasserted
TruPort
= the DTR is asserted whenever either a connect or an accept
mode tunnel connection is active with the Telnet Protocol RFC2217 saying
that the remote DSR is asserted.
Asserted while connected
= the DTR is asserted whenever either a
connect or an accept mode tunnel connection is active.
Continuously asserted
Tunnel Packing Mode
Settings
Description
Mode
Configure the Tunnel Packing Mode.
Choices are:
Disable
= Data not packed.
Timeout
= data sent after timeout occurs.
Send Character
= data sent when the Send Character is read on the Serial
Line.
Threshold
Set the threshold (byte count). If the received serial data reaches this
threshold, then the data will be sent on the network.
Valid range is 100 to
1450 bytes.
Default is 512.