Lantronix XPort Pro LX6 xPort Pro Lx6 - User Guide - Page 33
To Con Tunnel Accept Mode Settings, Using Web Manager, Using the CLI, Using XML, Connect Mode
![]() |
View all Lantronix XPort Pro LX6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
6: Line and Tunnel Settings Tunnel Accept Mode Settings (continued) Password Prompt for Password Email on Connect Email on Disconnect CP Output Description Enter a password. This password can be up to 31 characters in length and must contain only alphanumeric characters and punctuation. When set, clients must send the correct password string to the unit within 30 seconds from opening network connection in order to enable data transmission. The password sent to the unit must be terminated with one of the following: 0A (Line Feed) 00 (Null) 0D 0A (Carriage Return/Line Feed) 0D 00 (Carriage Return/Null) If, Prompt for Password is set to Enabled and a password is provided, the user will be prompted for the password upon connection. Select Enabled or Disabled (to enable or disable). This option will only appear if a password is specified above. Select an email profile number to which an email notification will be sent upon the establishment of an accept mode tunnel. Select an email profile number to which an email notification will be sent upon the disconnection of an accept mode tunnel. Enter the CP Output Group whose value should change when a connection is established and dropped. Connection Value specifies the value to set the CP Group to when a connection is established. Disconnection Value specifies the value to set the CP Group to when the connection is closed. To display the "Connection Value" and "Disconnection Value", first enter a "CP Output Group", then click outside that field. To Configure Tunnel Accept Mode Settings Using Web Manager To configure the Accept Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Accept Mode. Using the CLI To enter Tunnel 1 Accept Mode command level: enable -> tunnel 1 -> accept Using XML Include in your file: Connect Mode In Connect Mode, the XPort Pro Lx6 continues to attempt an outgoing connection on the network, until established. If the connection attempt fails or the connection drops, then it retries after a timeout. The remote node on the network must listen for the Connect Mode's connection. For Connect Mode to function, it must be enabled, have a remote station (node) configured, and a remote port configured (TCP or UDP). When established, Connect Mode is always on. Enter the remote station as an IPv4 or IPv6 address or DNS name. The XPort Pro Lx6 will not make a connection unless it can resolve the address. XPort® Pro Lx6 Embedded Device Server User Guide 33
![](/manual_guide/products/lantronix-xport-pro-lx6-xport-pro-lx6-user-guide-891c1c4/33.png)