Lenovo ThinkCentre M91p Hardware Maintenance Manual - Page 66
Voltage Sensors Test Passed, Voltage Sensors failure
View all Lenovo ThinkCentre M91p manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Diagnostic Error Code 086-199-XXX Mouse Port interface test failed, cause unknown 089-000-XXX Microprocessor Test Passed 089-XXX-XXX Microprocessor failure 089-195-XXX Microprocessor Test aborted by user 089-196-XXX Microprocessor test halt, error threshold exceeded 089-197-XXX Microprocessor test warning 089-198-XXX Microprocessor test aborted 089-199-XXX Microprocessor test failed, cause unknown 170-000-XXX Voltage Sensor(s) Test Passed 170-0XX-XXX Voltage Sensor(s) failure 170-195-XXX Voltage Sensor(s) Test aborted by user 170-196-XXX Voltage Sensor(s) test halt, error threshold exceeded 170-197-XXX Voltage Sensor(s) test warning 170-198-XXX Voltage Sensor(s) test aborted FRU/Action 1. See "Undetermined problems" on page 66. 2. Flash the system and re-test. See "Updating (flashing) the BIOS from a disc" on page 186. 3. Replace component under function test. No action 1. Microprocessor(s) 2. System board Information only Restart the test, if necessary. 1. Press F3 to review the log file. 2. Restart the test to reset the log file. 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6 "Using the Setup Utility program" on page 41. 2. Re-run the test. 3. Replace the component that is called out in warning statement. 4. Replace the component under test. 1. Flash the system. See "Updating (flashing) the BIOS from a disc" on page 186. 2. Go to "Undetermined problems" on page 66. 1. See "Undetermined problems" on page 66. 2. Flash the system and re-test. See "Updating (flashing) the BIOS from a disc" on page 186. 3. Replace component under function test. No action 1. Flash system 2. System board Information only Restart the test, if necessary. 1. Press F3 to review the log file. 2. Restart the test to reset the log file. 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6 "Using the Setup Utility program" on page 41. 2. Re-run the test. 3. Replace the component that is called out in warning statement. 4. Replace the component under test. 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6 "Using the Setup Utility program" on page 41. 2. Flash the system and re-test. See "Updating (flashing) the BIOS from a disc" on page 186. 3. Go to "Undetermined problems" on page 66. 60 ThinkCentre Hardware Maintenance Manual