Symptom-to-FRU index, Numeric error codes

Page 52 highlights

Symptom-to-FRU index The symptom-to-FRU index lists symptoms and errors and their possible causes. The most likely cause is listed first, in boldface type. Note: Do the FRU replacement or other actions in the sequence shown in the column headed ″FRU or action, in Sequence″. If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a non-defective FRU. This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next. A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number. If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to "Intermittent problems" on page 52. Note: For an IBM devices not supported by diagnostic codes in the ThinkPad notebook computers, see the manual for that device. Numeric error codes Symptom or error FRU or action, in sequence 0175 1. System board. Bad CRC1, stop POST task. The EEPROM checksum is not correct. 0187 1. System board. EAIA data access error 0190 Critical low battery error. 1. Critical low battery error. Charge the battery pack. 2. Battery pack. 0193 1. Enter the supervisor RF antenna has been removed. password. 0194The computer has been 1. Enter the supervisor carried through a security gate. password. 48 ThinkPad X20, X21, X22, X23, X24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Symptom-to-FRU index
The symptom-to-FRU index lists symptoms and errors and
their possible causes. The most likely cause is listed first,
in boldface type.
Note:
Do the FRU replacement or other actions in the
sequence shown in the column headed
FRU or
action, in Sequence
. If replacing a FRU does not
solve the problem, put the original part back in the
computer. Do not replace a non-defective FRU.
This index can also help you determine, during regular
servicing, what FRUs are likely to need to be replaced
next.
A numeric error is displayed for each error detected in
POST or system operation. In the displays, n can be any
number.
If no numeric code is displayed, check the narrative
descriptions of symptoms. If the symptom is not described
there, go to
Intermittent problems
on page 52.
Note:
For an IBM devices not supported by diagnostic
codes in the ThinkPad notebook computers, see the
manual for that device.
Numeric error codes
Symptom or error
FRU or action, in sequence
0175
Bad CRC1, stop POST task.
The EEPROM checksum is not
correct.
1.
System board
.
0187
EAIA data access error
1.
System board
.
0190
Critical low battery error.
1.
Critical low battery error.
Charge the battery pack.
2.
Battery pack.
0193
RF antenna has been removed.
1.
Enter the supervisor
password.
0194
The computer has been
carried through a security gate.
1.
Enter the supervisor
password.
48
ThinkPad X20, X21, X22, X23, X24