LiftMaster JDC Installation Manual - English French Spanish - Page 32
Operating Modes, B2 Mode, B2 / T One Time Close, B2 / Ts Timer Secure, C2 Mode Default
View all LiftMaster JDC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Programming (continued) Operating Modes This operator is programmed to function in one of four different operating modes. See the rest of this section for more detailed information. B2 MODE • Works with buttons on wall controller, myQ Facility®, wired 3-Button Wall Controller, and 3-Button Transmitter; momentary to open, stop,and close. • Works with Single Button Control and Single Button Transmitter; momentary to open, stop, close, and stop & reverse. B2 / T ONE TIME CLOSE) • After the TTC timer elapses operator will close the door. • TTC Timer will be active at the Open Limit or at a defined mid-stop. • The CLOSE button immediately closes the door. • The STOP button cancels the TTC for that cycle (no automatic motion). • The OPEN button resets the TTC timer. • TTC will be disabled if the door reverses from an obstruction. • A Monitored Entrapment Protection device is required to be connected for downward movement. Monitored Safety devices are Auto-Learned or manually configured through the wall control menu.. • A Monitored Entrapment Protection device activation will reverse the door to its Open limit. An activated Monitored Entrapment Protection device can be overridden with 5 seconds of constant pressure on the Wall Control Close button. Timer To Close is available in B2 Mode with two settings. The user can select a desired Timer to Close (TTC) timer under the Timers menu. In B2 the Car Dealer feature is available. The Car Dealer input (typically a treadle switch, loop detector, or motion sensor) will open the door to mid-stop, and TTC will be enabled. Repeated Car Dealer Input will not open the door beyond the mid-stop and will reset the TTC timer. TTC can be set either to one time close or timer secure • Timer Defeat Input will stop the TTC timer B2 / TS (TIMER SECURE) • After TTC timer elapses operator will close door. • TTC Timer will be active anywhere above close limit. The CLOSE button immediately closes the door. • The STOP button resets the TTC timer (held button will pause, release resets) • The OPEN button resets the TTC timer. • LMEP activation resets the timer • TTC will be enabled after Monitored Entrapment Protection device activation reverses the door to its Open limit. The controller will make infinite attempts to close the door until it reaches close limit. • Timer Defeat Input will stop the TTC timer In B2 the All Fly feature is available. (FSTS Mode) • The All Fly input (typically a mushroom button) will open the door to its Open limit, bypassing a midstop, and TTC will be enabled. • The CLOSE button immediately closes the door. • The STOP button resets the TTC timer (held button will pause, releasing the button will reset). • The OPEN button resets the TTC timer. • The controller will make infinite attempts to close the door until the safety obstruction is cleared. • TTC will be enabled after Monitored Entrapment Protection activation reverses the door to its Open limit. • Timer Defeat Input will stop TTC timer C2 MODE (DEFAULT) • Works with buttons on wall controller, wired 3-Button Wall Controller, and 3-Button Transmitter*; momentary to open, stop, and constant pressure to close. • Works with Single Button Control and Single Button Transmitter*; momentary to open, stop, and stop & reverse. • Works without a Monitored Entrapment Protection device learned, but can operate if a Monitored Entrapment Protection device is learned and connected for downward movement. • Monitored Entrapment Protection device activation will reverse the door to its Open limit. An activated Monitored Entrapment Protection device can be overridden with 5 seconds of constant pressure on the Wall Control Close button. *Constant Pressure to Close is not available from a remote control device (transmitter or myQ® Business™). 32